m+Medelevator.RU
← Поиск публикаций
Gait & posture · 2023

Shoulder brace has no detrimental effect on basic spatio-temporal gait parameters and functional mobility after arthroscopic rotator cuff repair.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Familiari Filippo, Mercurio Michele, Arenas-Miquelez Antonio, Barone Alessandro, Greco Francesca, Emerenziani Gian Pietro, Gasparini Giorgio, Galasso Olimpio

Аннотация

BACKGROUND: The risk of falls in patients undergoing orthopedic procedures is significant in terms of health and socioeconomic effects.

RESEARCH QUESTION: Is there an influence of the shoulder abduction brace (SAB) on gait parameters in patients undergoing arthroscopic rotator cuff repair (ARCR)?

METHODS: Thirty-five patients undergoing ARCR, who used a 15° SAB in the postoperative period, were included in a prospective study. Participants underwent gait analysis preoperatively (T0), 24 h after surgery (T1), 1 week (T2), and 4 weeks after surgery (1 week after SAB removal) (T3) by using a wearable inertial sensor (BTS G-Walk sensor). Gait Parameters (cadence, speed, right (R) and left (L) step length, gait and propulsion-R and L symmetry indices) and functional mobility (agility and balance) were assessed using the 10-meter test (10MWT) and the Timed Up and Go (TUG) test, respectively.

RESULTS: There were 22 men and 13 women with a median age of 56 (IQR 48.0-61.0) years. The right upper limb was involved in 83% of cases. Regarding the 10MWT, speed was significantly higher at T0 than at T1 (p < 0.01) and significantly lower at T1 than at T3 (p < 0.05). Cadence was significantly lower at T1 than at T3 (p < 0.05). Propulsion-R was significantly higher at T3 than at T1 (p < 0.01), whereas propulsion-L was significantly lower at T1 than at T0 (p < 0.05) and significantly higher at T2 and T3 than T1 (p < 0.01 for all). No significant differences were found for R and L step lengths as well as for symmetry index (p > 0.05). Regarding TUG test, the final turning phase was significantly higher at T2 than at T3 (p < 0.01).

SIGNIFICANCE: The results demonstrated that the use of the SAB affected gait speed and propulsion only 24 h after ARCR, but no effects were reported at long-term observations.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты