MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcms.2008.07.006

Медицинская библиотека · Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery · 2008

Accuracy and repeatability of cone-beam computed tomography (CBCT) measurements used in the determination of facial indices in the laboratory setup.

Moerenhout Bernard A M M L, Gelaude Frederik, Swennen Gwen R J, Casselman Jan W, Van Der Sloten Jos, Mommaerts Maurice Y

Сравнительное исследованиеСтатьяВалидационное исследованиеПеревод пока не подготовлен

Аннотация

AIM: To assess the three dimensional (3D) surface accuracy of a phantom's face acquired from a cone-beam computed tomography (CBCT) scan and to determine the reliability of selected cephalometric measurements performed with Maxilim software (Medicim N.V., Mechelen, Belgium).

MATERIAL AND

METHODS

A mannequin head was imaged with a CBCT (I-CAT, Imaging Sciences International, Inc., Hatfield, USA). The data were used to produce 3D surface meshes (Maxilim and Mimics, Materialise N.V., Leuven, Belgium) which were compared with an optical surface scan of the head using Focus Inspection software (Metris N.V., Leuven, Belgium). The intra- and inter-observer reliability for the measurement of distances between facial landmarks with Maxilim 3D cephalometry were determined by calculating Pearson correlation coefficients and intraclass correlation (ICC). The Dahlberg formula was used to assess the method error (ME).

RESULTS

(1) The maximal range of the 3D mesh deviations was 1.9 mm for Maxilim, and 1.8mm for Mimics segmentation. (2) Test-retest and inter-observer reliability were high; Pearson's correlation coefficient was 1.000 and the ICC was 0.9998. The ME of the vertical measurements was a little larger than that calculated for the width measurements. Maximum ME was 1.33 mm.

CONCLUSIONS

The 3D surface accuracy of CBCT scans segmented with Maxilim and Mimics software is high. Maxilim also shows satisfactory intra- and inter-assessor reliability for measurement of distances on a rigid facial surface.

Для цитирования: Moerenhout Bernard A M M L, Gelaude Frederik, Swennen Gwen R J, Casselman Jan W, Van Der Sloten Jos, Mommaerts Maurice Y. Accuracy and repeatability of cone-beam computed tomography (CBCT) measurements used in the determination of facial indices in the laboratory setup.. Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery. 2008. DOI: 10.1016/j.jcms.2008.07.006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.