m+Medelevator.RU
← Поиск публикаций
Asian Pacific journal of cancer prevention : APJCP · 2014

CEA, AFP, CA125, CA153 and CA199 in malignant pleural effusions predict the cause.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Wang Xin-Feng, Wu Yan-Hua, Wang Mao-Shui, Wang Yun-Shan

Аннотация

Determination of the cause of malignant pleural effusions is important for treatment and management, especially in cases of unknown primaries. There are limited biomarkers available for prediction of the cause of malignant pleural effusion in clinical practice. Hence, we evaluated pleural levels of five tumor biomarkers (CEA, AFP, CA125, CA153 and CA199) in predicting the cause of malignant pleural effusion in a retrospective study. Kruskal-Wallis or Mann-Whitney U tests were carried out to compare levels of tumor markers in pleural effusion among different forms of neoplasia - lung squamous cell carcinoma, adenocarcinoma, or small cell carcinoma, mesothelioma, breast cancer, lymphoma/leukemia and miscellaneous. Receiver operator characteristic analysis was performed to evaluate sensitivity and specificity of biomarkers. The Kruskal-Wallis test showed significant differences in levels of pleural effusion CEA (P<0.01), AFP (P<0.01), CA153 (P<0.01) and CA199 (P<0.01), but not CA125 (P>0.05), among the seven groups. Receiver operator characteristic analysis showed that, compared with other four tumor markers, CA153 was the best biomarker in diagnosing malignant pleural effusions of lung adenocarcinoma (area under curve (AUC): 0.838 (95%confidence interval: 0.787, 0.888); cut-off value: 10.2U/ ml; sensitivity: 73.2% (64.4-80.8)%, specificity: 85.2% (77.8-90.8)%), lung squamous cell carcinoma (AUC: 0.716 (0.652, 0.780); cut-off value: 14.2U/ml; sensitivity: 57.6% (50.7-64.3)%, specificity: 91.2% (76.3-98.0)%), and small-cell lung cancer (AUC: 0.812 (0.740, 0.884); cut-off value: 9.7U/ml; sensitivity: 61.5% (55.0-67.8)%, specificity: 94.1% (71.2-99.0)%); CEA was the best biomarker in diagnosing MPEs of mesothelioma (AUC: 0.726 (0.593, 0.858); cut-off value: 1.43ng/ml; sensitivity: 83.7% (78.3-88.2)%, specificity: 61.1% (35.8-82.6)%) and lymphoma/leukemia (AUC: 0.923 (0.872, 0.974); cut-off value: 1.71ng/ml; sensitivity: 82.8% (77.4-87.3)%, specificity: 92.3% (63.9-98.7)%). Thus CA153 and CEA appear to be good biomarkers in diagnosing different causes of malignant pleural effusion. Our findings implied that the two tumor markers may improve the diagnosis and treatment for effusions of unknown primaries.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты