Usefulness of a mobile phone application for respiratory rate measurement in adult patients.

Suzuki Ryuji, Takada Toshihiko, Takeshima Taro, Hayashi Michio, Miyashita Jun, Azuma Teruhisa, Usui Michiko, Hamaguchi Sugihiro, Fukuma Shingo, Maehara Kazuhira, Fukuhara Shunichi

СтатьяПеревод пока не подготовлен

Аннотация

AIMS: Respiratory rate measurement is one of the core nursing skills for early detection of deterioration of a patient's condition. Nevertheless, it is sometimes bothersome to visually measure respiratory rate over 1 min. Respiratory rate measurement using a mobile phone application "RRate" has been reported to be accurate and completed in a short time. However, it has only been investigated in children. The aim of this study was to validate the "RRate" compared with the 1-min method in adult patients.

METHODS

This was a cross-sectional study in the setting of a nursing school. Videos of the movement of the thorax during respiration of adult patients were made. Nursing students watched these videos and measured respiratory rate with each method. Bland-Altman analysis was used to calculate bias and limits of agreement. The times taken for the measurements were compared using a t test.

RESULTS

A total of 59 nursing students participated. When compared to the reference measurement, the one measured using "RRate" and the one measured over 1 min showed a bias of 0.40 breaths per minute and 0.65 breaths per minute, limits of agreement of -2.86 to 3.67 breaths per minute and -2.11 to 3.41 breaths per minute, respectively. The mean measurement time for "RRate" was 22.8 s (95% CI 13.9-36.6), which was significantly shorter than the 65.8 s (95% CI 61.0-73.2) for the measurement over 1 min (p < .001).

CONCLUSIONS

Respiratory rate can be measured accurately in a shorter time using a mobile phone application in adult patients.

Для цитирования: Suzuki Ryuji, Takada Toshihiko, Takeshima Taro, Hayashi Michio, Miyashita Jun, Azuma Teruhisa, Usui Michiko, Hamaguchi Sugihiro, Fukuma Shingo, Maehara Kazuhira, Fukuhara Shunichi. Usefulness of a mobile phone application for respiratory rate measurement in adult patients.. Japan journal of nursing science : JJNS. 2022. DOI: 10.1111/jjns.12481.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.