Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery · 2014

High-resolution microendoscope images of middle ear cholesteatoma and surrounding tissue: evaluation of interobserver concordance.

Сравнительное исследованиеОценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Bradley James, Jiang Nancy, Levy Lauren, Richards-Kortum Rebecca, Sikora Andrew, Smouha Eric

Аннотация

OBJECTIVE: Investigate how accurately otolaryngologists could differentiate between images obtained with high-resolution microendoscopy (HRME) of ex vivo cholesteatoma specimens and surrounding middle ear epithelium.

STUDY DESIGN: HRME images of surgically resected cholesteatoma and middle ear epithelium were obtained and otolaryngologists classified these images.

SETTING: Tertiary medical center.

SUBJECTS AND METHODS: Resected cholesteatoma and middle ear epithelium were stained with a contrast agent, proflavine, and HRME images were captured. Specimens were sent for standard histopathology and compared with HRME images. Quality-controlled images were used to assemble a training set. After viewing training images, otolaryngologists without prior cholesteatoma HRME experience reviewed and classified test images.

RESULTS: Ten cholesteatoma and 9 middle ear specimens were collected, of which 17 representative cholesteatoma and 19 middle ear epithelium images were extracted for a testing set. Qualitative analysis for concordance between HRME images and histological images yielded a strong correlation between modalities. The mean accuracy of all reviewers in correctly identifying images was 95% (95% confidence interval [CI], 92%-98%). The sensitivity to correctly detect cholesteatoma images was 98% (95% CI, 93%-100%), and the specificity was 92% (95% CI, 87%-97%). The Fleiss kappa interrater reliability score was 0.83, (95% CI, 0.77-0.89).

CONCLUSIONS: Medical professionals can quickly be trained to accurately distinguish between HRME images of cholesteatoma and normal middle ear epithelium, both of which have distinct imaging characteristics. Real-time HRME optical imaging can potentially improve the results of otologic surgery by allowing for extirpation of cholesteatomas while eliminating residual disease.