Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery · 2013
Ototoxicity of polymyxin B, neomycin, and hydrocortisone suspension in tympanoplasty surgery.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
House James R, House Laura K
Аннотация
OBJECTIVES: (1) To determine the safety of using a commercially available suspension of polymyxin B, neomycin, and hydrocortisone (PNH) in tympanoplasty surgery. (2) To apply evidence-based medicine to tympanoplasty surgery when considering potential ototoxicity.
STUDY DESIGN: Case series with chart review.
SETTING: Tertiary otology practice, single surgeon.
METHODS: Approval for this study was obtained from the St. Dominic-Jackson Memorial Hospital Institutional Review Board. Data were gathered on 272 consecutive type 1, underlay tympanoplasties for which both pre- and postoperative audiometric data were available over a 10-year period. In each surgery, gelatin sponge saturated in a commercially available PNH suspension was placed in the middle ear to support the graft. Patients ranged in age from 3 years to 79 years. Preoperative and postoperative bone conduction thresholds were measured at 500, 1000, 2000, 3000, and 4000 Hz.
RESULTS: The average change in sensorineural hearing as measured by bone conduction thresholds was negligible, with a slight improvement in all frequencies tested except 4000 Hz. The changes by frequencies were as follows: 500 Hz (-1.624 dB), 1000 Hz (-1.399 dB), 2000 Hz (-0.975 dB), 3000 Hz (-0.596 dB), and 4000 Hz (+0.560 dB). The 5-frequency average change was -0.545 dB.
CONCLUSIONS: The commonly used otic solution containing polymyxin B, neomycin, and hydrocortisone demonstrates no ototoxicity in tympanoplasty surgery and is safe to use in this setting.
STUDY DESIGN: Case series with chart review.
SETTING: Tertiary otology practice, single surgeon.
METHODS: Approval for this study was obtained from the St. Dominic-Jackson Memorial Hospital Institutional Review Board. Data were gathered on 272 consecutive type 1, underlay tympanoplasties for which both pre- and postoperative audiometric data were available over a 10-year period. In each surgery, gelatin sponge saturated in a commercially available PNH suspension was placed in the middle ear to support the graft. Patients ranged in age from 3 years to 79 years. Preoperative and postoperative bone conduction thresholds were measured at 500, 1000, 2000, 3000, and 4000 Hz.
RESULTS: The average change in sensorineural hearing as measured by bone conduction thresholds was negligible, with a slight improvement in all frequencies tested except 4000 Hz. The changes by frequencies were as follows: 500 Hz (-1.624 dB), 1000 Hz (-1.399 dB), 2000 Hz (-0.975 dB), 3000 Hz (-0.596 dB), and 4000 Hz (+0.560 dB). The 5-frequency average change was -0.545 dB.
CONCLUSIONS: The commonly used otic solution containing polymyxin B, neomycin, and hydrocortisone demonstrates no ototoxicity in tympanoplasty surgery and is safe to use in this setting.