MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/1746-160x-3-38

Медицинская библиотека · Head & face medicine · 2007

Applied mechanics of the Puricelli osteotomy: a linear elastic analysis with the finite element method.

Puricelli Edela, Fonseca Jun Sérgio Ono, de Paris Marcel Fasolo, Sant'Anna Hervandil

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Surgical orthopedic treatment of the mandible depends on the development of techniques resulting in adequate healing processes. In a new technical and conceptual alternative recently introduced by Puricelli, osteotomy is performed in a more distal region, next to the mental foramen. The method results in an increased area of bone contact, resulting in larger sliding rates among bone segments. This work aimed to investigate the mechanical stability of the Puricelli osteotomy design.

METHODS

Laboratory tests complied with an Applied Mechanics protocol, in which results from the Control group (without osteotomy) were compared with those from Test I (Obwegeser-Dal Pont osteotomy) and Test II (Puricelli osteotomy) groups. Mandible edentulous prototypes were scanned using computerized tomography, and digitalized images were used to build voxel-based finite element models. A new code was developed for solving the voxel-based finite elements equations, using a reconditioned conjugate gradients iterative solver. The Magnitude of Displacement and von Mises equivalent stress fields were compared among the three groups.

RESULTS

In Test Group I, maximum stress was seen in the region of the rigid internal fixation plate, with value greater than those of Test II and Control groups. In Test Group II, maximum stress was in the same region as in Control group, but was lower. The results of this comparative study using the Finite Element Analysis suggest that Puricelli osteotomy presents better mechanical stability than the original Obwegeser-Dal Pont technique. The increased area of the proximal segment and consequent decrease of the size of lever arm applied to the mandible in the modified technique yielded lower stress values, and consequently greater stability of the bone segments.

CONCLUSION

This work showed that Puricelli osteotomy of the mandible results in greater mechanical stability when compared to the original technique introduced by Obwegeser-Dal Pont. The increased area of the proximal segment and consequent decrease of the size of lever arm applied to the mandible in the modified technique yield lower stress values and displacements, and consequently greater stability of the bone segments.

Для цитирования: Puricelli Edela, Fonseca Jun Sérgio Ono, de Paris Marcel Fasolo, Sant'Anna Hervandil. Applied mechanics of the Puricelli osteotomy: a linear elastic analysis with the finite element method.. Head & face medicine. 2007. DOI: 10.1186/1746-160x-3-38.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.