MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1088/1361-6498/ae9ecf

Медицинская библиотека · Journal of radiological protection : official journal of the Society for Radiological Protection · 2026

Query-based prediction of 3D x-ray scatter fields in an interventional suite using a transformer model.

Rettig Niklas, Schülein Patrick, Bukschat Yannick, Vetter Marcus

СтатьяПеревод пока не подготовлен

Аннотация

Fluoroscopy-guided interventions expose clinical staff to x-ray scatter radiation, motivating accurate three-dimensional scatter-field predictions for radiation protection planning. Monte Carlo (MC) simulations provide reference accuracy but require minutes to hours of computation, while analytical models are faster but often lack spatial fidelity in complex geometries. We present a transformer-based model for scatter dosimetry in a single simulated interventional suite with fixed room geometry and object inventory, supporting near real-time inference on localised subvolumes and interactive runtimes for whole-room evaluation. We train a separate transformer-based model for each target quantity: air kerma per source photon, transported energy, and energy fluence per source photon. Each predictor encodes spectrum and technique parameters and represents room objects and their poses as a set of scene tokens. Predictions are obtained by coordinate-conditioned regression at queried voxel locations, so inference can be restricted to selected subvolumes and runtime scales with the number of queried voxels. The training set comprisessimulated configurations with varied C-arm poses, spectra, patient-table and patient phantom positions. On an independent test set ofconfigurations, the model achieves medianfor log-transformed targets and structural similarity around. In linear units, medianvalues arefor air kerma per source photon,for transported energy, andfor energy fluence. Full-room inference, reconstructing the effective grid of aboutmillion voxels, takeson an NVIDIA L40S GPU compared tofor MC simulation, yieldingaspeed-up. These results represent a step toward interactive, room-scale radiation protection planning, enabling rapid what-if analyses of staff positioning and procedure planning.

Для цитирования: Rettig Niklas, Schülein Patrick, Bukschat Yannick, Vetter Marcus. Query-based prediction of 3D x-ray scatter fields in an interventional suite using a transformer model.. Journal of radiological protection : official journal of the Society for Radiological Protection. 2026. DOI: 10.1088/1361-6498/ae9ecf.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.