MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/rlu.0000000000006660

Медицинская библиотека · Clinical nuclear medicine · 2026

18F-FAPI PET/CT for Assessing Inflammation-related Activity in Recurrent In-Stent Restenosis After Percutaneous Coronary Intervention: A Prospective Comparison With 18F-FDG.

Xie Hangyu, Han Xu, Nan Nan, Xie Xiaofen, Yang Zihe, Du Juan, Qian Haiyan, Mi Hongzhi, Dong Wei

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Persistent inflammatory activity may contribute to recurrent in-stent restenosis (ISR) after percutaneous coronary intervention (PCI). This study aimed to evaluate the efficacy of 18F-FAPI PET/CT for detecting inflammation-related activity in recurrent ISR and to compare it with 18F-FDG PET/CT.

PATIENTS AND

METHODS

Patients with recurrent ISR after PCI and suspected persistent inflammatory mechanisms were prospectively enrolled. All patients underwent 18F-FAPI PET/CT, and 32 also underwent 18F-FDG PET/CT within 1 week. Patients were classified as having inflammation-related ISR or non-inflammation-related ISR by multidisciplinary adjudication. Visual and semiquantitative PET parameters were compared between groups and tracers.

RESULTS

Forty-four patients (mean age, 56.8±10.3 y) were included, including 31 with inflammation-related ISR and 13 with non-inflammation-related ISR. 18F-FAPI PET/CT showed positive findings in all 31 patients with inflammation-related ISR, compared with 3 of 13 patients with non-inflammation-related ISR (100% vs. 23.1%). Visual score, SUVmax, SUVmean, TBRblood, and TBRliver were all significantly higher in inflammation-related ISR than in non-inflammation-related ISR (all P<0.001). In the dual-tracer subgroup (n=32), 18F-FAPI PET/CT detected all inflammation-related ISR cases (20/20, 100%), whereas 18F-FDG PET/CT detected 8 of 20 (40.0%) (P<0.001). Compared with 18F-FDG, 18F-FAPI showed higher visual scores and significantly greater tracer uptake in inflammation-related ISR (all P<0.05).

CONCLUSIONS

18F-FAPI PET/CT demonstrated higher detectability of inflammation-related activity in recurrent ISR and provided better lesion-to-background contrast than 18F-FDG PET/CT. These findings support its potential role in the noninvasive assessment of coronary inflammatory activity after PCI.

Для цитирования: Xie Hangyu, Han Xu, Nan Nan, Xie Xiaofen, Yang Zihe, Du Juan, Qian Haiyan, Mi Hongzhi, Dong Wei. 18F-FAPI PET/CT for Assessing Inflammation-related Activity in Recurrent In-Stent Restenosis After Percutaneous Coronary Intervention: A Prospective Comparison With 18F-FDG.. Clinical nuclear medicine. 2026. DOI: 10.1097/rlu.0000000000006660.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.