Evaluation of click evoked otoacoustic emissions in newborns: effects of time-windowing.

Tognola G, Grandori F, Ravazzani P

СтатьяПеревод пока не подготовлен

Аннотация

The objective of this study was to investigate the effects of time-windowing on click evoked otoacoustic emissions (CEOAEs); 466 CEOAEs from full-term babies were considered. Data were acquired according to the default ILO88 response window (2.5-20 ms). Because CEOAEs are time-varying signals, each emission was analysed by means of the wavelet transform (WT), a technique which allows a simultaneous representation of the time and frequency features of a signal. By means of the WT it was possible to extract the temporal pattern of the elementary frequency components of the compound emissions. The effects of time-windowing were evaluated on each single emission component: rms and correlation values were computed from six 2.5-ms long time windows in the 2.5-17.5 ms range. Results indicated that both rms and correlation were not constant with time but reached a maximum in specific time-windows, depending on the frequency of the component. For low-frequency components, the correlation typically had a maximum in the interval 10-12.5 ms, whereas high-frequency components had a maximum around 5 ms. Above 12.5 ms, the correlation was greatly decreased for all frequency components. As a result, the comparison between the performance of the default ILO88 window (2.5-20 ms) and the window 2.5-12.5 ms showed that for all frequencies in the 1.5-6 kHz range there was a statistically significant improvement in the correlation. No improvement was observed for frequencies below 1.5 kHz because of their contamination by the residual background noise.

Для цитирования: Tognola G, Grandori F, Ravazzani P. Evaluation of click evoked otoacoustic emissions in newborns: effects of time-windowing.. Audiology : official organ of the International Society of Audiology. 1999. DOI: 10.3109/00206099909073014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.