MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2463/mrms.9.23

Медицинская библиотека · Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine · 2010

MR imaging of the cochlear modiolus after intratympanic administration of Gd-DTPA.

Kawai Hisashi, Naganawa Shinji, Ishihara Shunichi, Sone Michihiko, Nakashima Tsutomu

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: We evaluated whether enhancement of the cochlear modiolus could be visualized 24 hours after intratympanic injection of gadolinium diethylenetriamine penta-acetic acid (Gd-DTPA) using a 3-dimensional real inversion recovery sequence combined with a 32-channel head coil at 3 tesla. Intratympanic injection of Gd-DTPA has been reported for visualizing endolymphatic hydrops in Meniere's disease, and its use has shown communication between the cochlear perilymph and cerebrospinal fluid in the internal auditory canal. Although the cochlear modiolus has been considered the route for this communication, this has not been confirmed through direct visualization of its enhancement.

MATERIALS AND

METHODS

We qualitatively and quantitatively evaluated the presence of contrast enhancement in the modiolus in 19 patients with clinically suspected endolymphatic hydrops or hearing loss who underwent imaging as described above.

RESULTS

The contrast ratio (CR) between the cochlear modiolus and cerebellar white matter on the injected side was 1.09+/-1.23, and that on the non-injected side was -0.48+/-0.38 (P<0.01). In all subjects, the CR value was larger on the injected than non-injected side, and enhancement of the cochlear modiolus was also recognized visually.

CONCLUSIONS

Intratympanic Gd-DTPA can be administered to visualize enhancement of the cochlear modiolus and may thereby reveal its functional anatomy.

Для цитирования: Kawai Hisashi, Naganawa Shinji, Ishihara Shunichi, Sone Michihiko, Nakashima Tsutomu. MR imaging of the cochlear modiolus after intratympanic administration of Gd-DTPA.. Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine. 2010. DOI: 10.2463/mrms.9.23.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.