MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/md.0000000000050994

Медицинская библиотека · Medicine · 2026

Metallic versus plastic stents for the management of biliary obstruction: A GRADE-assessed systematic review and meta-analysis.

Malik Aleena Amir, Sharif Manal, Kareem Waqas, Qaseem Muhammad, Asad Yashfa, Rahman Saad, Hamza Ismail Tajudeen, Khan Husna, Khan Abdul Qayam, Sajjad Fatima, Nasir Ammn, Muhammad Anas, Nisa Hadia, Ayaz Hamna, Haq M Inzamam Ul, Kazi Naima, Aamir Samra, Nazar Spogmai, Afridi Uzma, Shahid Muhammad Waqar, Afridi Abdullah, Yousaf Kashif

СтатьяСистематический обзорМетаанализСравнительное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Biliary obstruction can be managed with metallic stents (MS) or plastic stents (PS), but comparative evidence across benign and malignant conditions remains uncertain. We conducted a systematic review and meta-analysis comparing MS and PS.

METHODS

PubMed, Embase, Scopus, Web of Science, and Cochrane CENTRAL were searched from inception to the search date. Randomized controlled trials and observational studies comparing MS with PS in patients with benign or malignant biliary obstruction were eligible. Primary analyses compared MS with PS across the overall eligible population, including both benign and malignant obstruction. Where sufficient outcome-specific data were available, subgroup analyses were performed according to disease etiology (benign vs malignant). Outcomes included functional success, adverse events, recurrent biliary obstruction (RBO), procedure time, and overall survival. Meta-analysis was performed with Hartung-Knapp sensitivity analyses.

RESULTS

Nine studies comprising 890 participants were included. Functional success was comparable between MS and PS (RR = 1.03, 95% confidence intervals [CI]: 0.96-1.11). Among 8 studies contributing adverse-event data, no significant difference was observed (RR = 1.37, 95% CI: 0.92-2.03; P = .123; I2 = 45.4%). Adverse events were higher with MS in malignant disease (RR = 1.74, 95% CI: 1.15-2.63) but not benign disease (RR = 1.01, 95% CI: 0.83-1.23; P for subgroup difference = .020). Hartung-Knapp analysis remained non-significant (RR = 1.37, 95% CI: 0.96-1.95; P = .078). MS showed a lower risk of RBO (RR = 0.61, 95% CI: 0.32-1.17; I2 = 93.1%), supported by Hartung-Knapp analysis (RR = 0.61, 95% CI: 0.41-0.91).

CONCLUSION

MS and PS demonstrated comparable functional success and overall adverse-event rates, although adverse events were higher with MS in malignant disease. MS may improve stent durability, but substantial heterogeneity limits certainty. Available studies did not demonstrate a consistent survival advantage. Further randomized trials are warranted.

Для цитирования: Malik Aleena Amir, Sharif Manal, Kareem Waqas, Qaseem Muhammad, Asad Yashfa, Rahman Saad, Hamza Ismail Tajudeen, Khan Husna, Khan Abdul Qayam, Sajjad Fatima, Nasir Ammn, Muhammad Anas, Nisa Hadia, Ayaz Hamna, Haq M Inzamam Ul, Kazi Naima, Aamir Samra, Nazar Spogmai, Afridi Uzma, Shahid Muhammad Waqar, Afridi Abdullah, Yousaf Kashif. Metallic versus plastic stents for the management of biliary obstruction: A GRADE-assessed systematic review and meta-analysis.. Medicine. 2026. DOI: 10.1097/md.0000000000050994.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.