MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1017/s0022215124000677

Медицинская библиотека · The Journal of laryngology and otology · 2024

Frequency-specific analysis of hearing outcomes after surgery for chronic ear diseases.

Cai Liangxuan, Wang TaiQin, Sun Huanhuan, Qiu Jinqing, Liu Jianzhi

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To examine the relationship between different surgical factors and frequency-specific hearing results following surgery for chronic ear disorders.

METHODS

We reviewed retrospectively data of 246 patients with chronic ear diseases who had surgery between January 2019 and December 2020. Seventy-three patients did not fulfil the criteria and were excluded. Air-conduction threshold, bone-conduction threshold and air-bone gap were tested at 250-4000 Hz, respectively. Frequency-specific results were investigated in relation to various surgical factors.

RESULTS

The radical mastoidectomy group and tympanoplasty group significantly improved in air-conduction threshold changes at every frequency. In the tympanoplasty group, air-bone gap at all frequencies except 4000 significantly improved. Air-conduction threshold improved at low and middle frequencies when ossicular reconstruction was conducted. In all groups, bone-conduction threshold data revealed significant improvements at 500, 1000, and 2000 Hz.

CONCLUSIONS

Hearing improved significantly post-operatively in air-conduction threshold and air-bone gap test, mainly at low and middle frequencies. Bone-conduction threshold improved significantly at 500-2000 Hz.

Для цитирования: Cai Liangxuan, Wang TaiQin, Sun Huanhuan, Qiu Jinqing, Liu Jianzhi. Frequency-specific analysis of hearing outcomes after surgery for chronic ear diseases.. The Journal of laryngology and otology. 2024. DOI: 10.1017/s0022215124000677.