MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/01652176.2026.2720640

Медицинская библиотека · The veterinary quarterly · 2026

Evaluation of a 0.05 T low-field MRI system for canine brain imaging via comparison with images acquired at 1.5 T field strength: a pilot cadaver study.

Burgers Elisabeth Maria, Miles Samantha, Veraa Stefanie, O'Reilly Thomas, van den Broek Ruben, Najac Chloé, Lena Beatrice, Webb Andrew

СтатьяСравнительное исследованиеОценочное исследованиеПеревод в очереди

Аннотация

Magnetic resonance imaging (MRI) systems continue to grow in number in veterinary and human medicine with higher field strength magnets increasingly available; however, the associated high costs have created healthcare inequities. This technical feasibility study aimed to evaluate a low-cost, portable, and permanent magnet-based 0.05 T low-field system (LF), originally designed for human neuroimaging, for assessing the canine brain. By using 23 canine cadavers, a scanning protocol was developed, consisting of transverse T1-weighted (T1w) and T2-weighted (T2w) sequences, and compared to a 1.5 T (HF) protocol for the visibility of 22 anatomical features. For the purpose of hydrocephalus evaluation, the LF system showed non-inferior detection of the lateral ventricles (LV) and mesencephalic aqueduct on T2w sequences with >90% conditional probability for detecting these features on the LF, given they were present on the HF. For T1w sequences, the LF system had inconclusive non-inferiority for detection of LV with 76.6% conditional probability. In summary, a canine brain scanning protocol was successfully developed for a 0.05 T MRI with preliminary evaluation suggestive that this device can aid with the detection of hydrocephalus. Future in vivo studies are required to evaluate the device's true clinical application.

Для цитирования: Burgers Elisabeth Maria, Miles Samantha, Veraa Stefanie, O'Reilly Thomas, van den Broek Ruben, Najac Chloé, Lena Beatrice, Webb Andrew. Evaluation of a 0.05 T low-field MRI system for canine brain imaging via comparison with images acquired at 1.5 T field strength: a pilot cadaver study.. The veterinary quarterly. 2026. DOI: 10.1080/01652176.2026.2720640.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.