MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.apradiso.2026.112899

Медицинская библиотека · Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026

Automated radiochemical synthesis of [68Ga]Ga-FAPI-4 employing modular lab standard with fixed-tubing non-cassette methodology: its preliminary clinical feasibility.

Sahu Sudeep, Chakraborty Avik, Lad Sangita, Rakshit Sutapa, Mitra Arpit, Tawate Megha, Upadhye Trupti, Sayed Adiba, Singh Abhishek, Sethe Yogita, Ray Muktikant, Basu Sandip

СтатьяПеревод пока не подготовлен

Аннотация

Fully automated, multiple patient dose preparation of [68Ga]Ga-FAPI-4 was standardized using a commercial fixed tubing (non-cassette) based automated module namely Eckert and Ziegler 'Modular-Lab Standard' (EZ-ML). The routine production of [68Ga]Ga-FAPI-4 with consistent and reproducible decay corrected (dc) radiochemical yield (RCY) and radiochemical purity (RCP) of 97.47 ± 0.26% and 99.18 ± 0.34% respectively was achieved in our hospital radiopharmacy unit, which was effectively used in our high-volume Nuclear Medicine Centre (NMC). The quality control parameters of the produced [68Ga]Ga-FAPI-4 were in accordance with the European Pharmacopoeia. The promising pre-clinical in-vitro and in-vivo results demonstrated the potential of the product for clinical use in targeting Fibroblast Activation Protein (FAP) overexpressed tumors. Comparable IC50 values for FAPI-4 (6.12 nM) and [68Ga]Ga-FAPI-4 (6.52 nM) confirmed preservation of FAP inhibitory activity after radiolabeling. PET/CT image of SCID mouse bearing HT-1080 xenografted tumor, at 1h post-injection, clearly delineated the tumor. The high degree of localization of the produced [68Ga]Ga-FAPI-4 in FAP overexpressed tumors visualized in clinical PET/CT scan of patients, demonstrated its successful use for diagnostic scans of patients having FAP overexpressed solid tumors.

Для цитирования: Sahu Sudeep, Chakraborty Avik, Lad Sangita, Rakshit Sutapa, Mitra Arpit, Tawate Megha, Upadhye Trupti, Sayed Adiba, Singh Abhishek, Sethe Yogita, Ray Muktikant, Basu Sandip. Automated radiochemical synthesis of [68Ga]Ga-FAPI-4 employing modular lab standard with fixed-tubing non-cassette methodology: its preliminary clinical feasibility.. Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine. 2026. DOI: 10.1016/j.apradiso.2026.112899.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.