MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/alz.71922

Медицинская библиотека · Alzheimer's & dementia : the journal of the Alzheimer's Association · 2026

Direction-specific biomarker profiles and clinical significance of plasma p-tau217/amyloid PET discordance in cognitively normal adults.

Huang Yanlu, Huang Lin, Cui Liang, Pan Fengfeng, Xie Fang, Guo Hongbo, Guo Qihao, Alzheimer's Disease Neuroimaging Initiative

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Plasma phosphorylated tau (p-tau)217 is increasingly used to triage amyloid testing, but the biological and clinical meaning of discordant plasma p-tau217 and amyloid positron emission tomography (PET) results in cognitively normal adults remains uncertain.

METHODS

We analyzed cognitively normal participants from the Chinese Preclinical Alzheimer's Disease Study (CPAS; n = 594) and the Alzheimer's Disease Neuroimaging Initiative (ADNI; n = 475). Amyloid PET positivity was defined as Centiloid ≥ 20. Cohort-specific p-tau217 positivity was defined using PET-anchored cutoffs with ≥ 0.90 specificity, yielding four p-tau/PET groups. Linear models assessed cross-sectional biomarker and cognitive differences; mixed-effects and Cox models assessed ADNI longitudinal Centiloid accumulation, cognitive trajectories, and clinical progression.

RESULTS

In cross-sectional analyses, compared to p-tau-/PET-, p-tau+/PET- had higher glial fibrillary acidic protein (GFAP) and neurofilament light chain (NfL) levels across cohorts; p-tau-/PET+ showed a lower plasma amyloid beta 42/40 ratio in ADNI; and p-tau+/PET+ showed the broadest multimodal abnormalities. In ADNI, both p-tau+ groups had higher clinical progression risk and faster decline in selected cognitive domains; both PET+ groups showed faster Centiloid accumulation. Faster Centiloid accumulation in p-tau+/PET- was observed only at lower specificity thresholds.

DISCUSSION: Discordant plasma p-tau217 and amyloid PET results should be interpreted according to both the positivity pattern and the p-tau217 cutoff applied. Distinguishing these patterns may aid risk stratification and longitudinal monitoring. Different p-tau217 operating points may support risk enrichment and prioritization for confirmatory amyloid testing, but require validation before clinical use.

Для цитирования: Huang Yanlu, Huang Lin, Cui Liang, Pan Fengfeng, Xie Fang, Guo Hongbo, Guo Qihao, Alzheimer's Disease Neuroimaging Initiative. Direction-specific biomarker profiles and clinical significance of plasma p-tau217/amyloid PET discordance in cognitively normal adults.. Alzheimer's & dementia : the journal of the Alzheimer's Association. 2026. DOI: 10.1002/alz.71922.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.