MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1378/chest.118.2.445

Медицинская библиотека · Chest · 2000

Serum KL-6 concentrations in dairy farmers.

Takahashi T, Munakata M, Ohtsuka Y, Satoh-Kamachi A, Sato R, Homma Y, Kawakami Y

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

STUDY

OBJECTIVES

Serum KL-6 (Krebs von den Lungen-6) has been recognized to be a marker for the activity of diffuse interstitial lung diseases. The purpose of the study is to evaluate serum KL-6 measurement as a marker for farmer's lung disease (FLD).

DESIGN

A cross-sectional survey of a cohort of dairy farmers. Retrospective measurement of KL-6 stored serum samples from those dairy farmers previously screened for FLD.

SETTING

University hospital screening project for FLD within a dairy-farming community in Japan.

PARTICIPANTS

Four hundred seventy-two dairy farmers were invited to attend a local clinic.

MEASUREMENTS AND

RESULTS

We examined serum KL-6 concentrations in 272 farmers. Subjects were classified into three groups: (1) 5 farmers with FLD, (2) 30 farmers with positive serum precipitating antibodies to Saccharopolyspora rectivirgula and/or Thermoactinomyces vulgaris without FLD (Ab(+)), and (3) 237 farmers without these antibodies (Ab(-)). Serum KL-6 concentrations in the FLD group were significantly higher than those in the Ab(+) and the Ab(-) groups (1,263 +/- 288 [SEM], 328 +/- 57, and 207 +/- 6 U/mL, respectively, p < 0.001). Serum KL-6 concentrations in those with FLD were significantly higher than KL-6 concentrations from stored screening samples from the same individual when FLD was not diagnosed (1,263 +/- 288 and 419 +/- 209 U/mL, respectively, p < 0.05). Serum KL-6 concentrations of the Ab(+) group were significantly higher than those of the Ab(-) group (p < 0.001). In the Ab(+) group, farmers with high serum KL-6 concentrations had lower permeability coefficients than farmers with normal serum KL-6 concentrations (p < 0.05). These results may suggest that subclinical FLD can be detected in farmers with high KL-6 concentrations and precipitating antibodies.

CONCLUSION

Serum KL-6 concentration can be a useful marker for assessing the activity of FLD and may be able to be used to detect subclinical disease.

Для цитирования: Takahashi T, Munakata M, Ohtsuka Y, Satoh-Kamachi A, Sato R, Homma Y, Kawakami Y. Serum KL-6 concentrations in dairy farmers.. Chest. 2000. DOI: 10.1378/chest.118.2.445.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.