Pediatric radiology · 2026
Ferumoxytol dose optimization for three-dimensional whole-heart magnetic resonance imaging in patients with congenital heart disease.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Erdem Sukran, Hussain Tarique, El Jerbi Aya, Erdem Orhan, Thai Lauren, Gaur Lasya, Greil Gerald F, Alsaied Tarek, Dzelebdzic Sanja, Zou Qing
Аннотация
BACKGROUND: Ferumoxytol is used off-label as a contrast agent for cardiovascular magnetic resonance (CMR). However, the dose-response relationship between ferumoxytol, longitudinal relaxation, and image quality in pediatric and young patients remains unclear.
OBJECTIVE: To evaluate the effects of sequential ferumoxytol dose escalation on three-dimensional (3D) whole-heart (WH) image quality and blood-pool nulling inversion time (TI), a physiologic surrogate of post-contrast T1 shortening.
MATERIALS AND METHODS: In this prospective study, 45 patients with congenital heart disease underwent ferumoxytol-enhanced 3D WH CMR at 1.5 T using sequential dose regimens (1 mg/kg→2 mg/kg or 2 mg/kg→3 mg/kg). Right coronary artery (RCA) image quality and visible length, contrast-to-noise ratio (CNR), and image quality of the cardiac chambers and great vessels, as well as diagnostic completeness, were assessed. Blood-pool and myocardial nulling TI were measured using Look-Locker sequences. Baseline-adjusted change-score regression was the primary analysis, with mixed-effects ANCOVA performed to model TI behavior while accounting for repeated within-patient measurements.
RESULTS: No significant differences were observed in CNR, RCA length, image quality, or diagnostic completeness between all doses (all P>0.05). Myocardial and blood-pool nulling TI shortened significantly with dose escalation (P≤0.02). Change in blood-pool TI after the second dose was strongly predicted by TI after the first dose (β=-0.63, P<0.001), whereas starting dose (1 mg/kg or 2 mg/kg) was not associated with TI change (P=0.70). At 1 mg/kg, prolonged myocardial nulling TI may encroach upon the systolic rest period.
CONCLUSIONS: Ferumoxytol-enhanced 3D WH imaging provides diagnostic-quality assessment across 1-3 mg/kg dosing. Dose-dependent TI shortening follows a nonlinear, saturating pattern, supporting optimized low-dose protocols.
OBJECTIVE: To evaluate the effects of sequential ferumoxytol dose escalation on three-dimensional (3D) whole-heart (WH) image quality and blood-pool nulling inversion time (TI), a physiologic surrogate of post-contrast T1 shortening.
MATERIALS AND METHODS: In this prospective study, 45 patients with congenital heart disease underwent ferumoxytol-enhanced 3D WH CMR at 1.5 T using sequential dose regimens (1 mg/kg→2 mg/kg or 2 mg/kg→3 mg/kg). Right coronary artery (RCA) image quality and visible length, contrast-to-noise ratio (CNR), and image quality of the cardiac chambers and great vessels, as well as diagnostic completeness, were assessed. Blood-pool and myocardial nulling TI were measured using Look-Locker sequences. Baseline-adjusted change-score regression was the primary analysis, with mixed-effects ANCOVA performed to model TI behavior while accounting for repeated within-patient measurements.
RESULTS: No significant differences were observed in CNR, RCA length, image quality, or diagnostic completeness between all doses (all P>0.05). Myocardial and blood-pool nulling TI shortened significantly with dose escalation (P≤0.02). Change in blood-pool TI after the second dose was strongly predicted by TI after the first dose (β=-0.63, P<0.001), whereas starting dose (1 mg/kg or 2 mg/kg) was not associated with TI change (P=0.70). At 1 mg/kg, prolonged myocardial nulling TI may encroach upon the systolic rest period.
CONCLUSIONS: Ferumoxytol-enhanced 3D WH imaging provides diagnostic-quality assessment across 1-3 mg/kg dosing. Dose-dependent TI shortening follows a nonlinear, saturating pattern, supporting optimized low-dose protocols.