DOI 10.3390/s26196182

Медицинская библиотека · Sensors (Basel, Switzerland) · 2026

Assessment of Task-Specific Gait and Balance Deficits in Chronic Low Back Pain Using Multi-Sensor Inertial Measurement Units.

Chien Yen-Chang, Koo Lik-Kang, Chang Chia-Wei, Chen Chien-Cheng, Chen Szu-Fu, Wang Fu-Cheng

СтатьяПеревод пока не подготовлен

Аннотация

Chronic low back pain (cLBP) compromises daily function, but associated balance deficits remain difficult to quantify using traditional scales. We recruited 50 participants with CLBP (age: 65.68 ± 11.84) and 50 age-matched controls (age: 65.26 ± 10.73) wearing multiple inertial measurement units (IMUs) to evaluate kinematics: average absolute angular velocity (Jω) and linear acceleration (Jα) across static (single-leg stance), perturbed (balance board), locomotor (walking, tandem gait), and transitional (five times sit-to-stand) tasks. Group differences were assessed using multivariate analysis of variance and Bonferroni-adjusted univariate tests. During the balance board test, Jω was significantly higher at the chest (p = 0.027) and hip (p = 0.003) in the CLBP group. Conversely, during the sit-to-stand tests, the CLBP group showed significantly lower Jα and Jω (p < 0.0001) at the hip. The CLBP group exhibited globally lower Jω (p < 0.01) during normal walking, while the AmpPR (p = 0.001) was exclusively reduced during tandem gait. These results suggest that multi-sensor IMU-based assessments provide a sensitive tool for detecting subtle, task-specific balance deficits in CLBP, indicating that rehabilitation should target rotational mobility and reactive control rather than core stiffening alone. Larger-scale and longitudinal research is still required to determine their clinical utility.

Для цитирования: Chien Yen-Chang, Koo Lik-Kang, Chang Chia-Wei, Chen Chien-Cheng, Chen Szu-Fu, Wang Fu-Cheng. Assessment of Task-Specific Gait and Balance Deficits in Chronic Low Back Pain Using Multi-Sensor Inertial Measurement Units.. Sensors (Basel, Switzerland). 2026. DOI: 10.3390/s26196182.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.