MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/sms.70387

Медицинская библиотека · Scandinavian journal of medicine & science in sports · 2026

Device-Measured 24-h Movement Behaviors and Arterial Intima-Media Thickness in Young Adults.

Suorsa Kristin, Laitinen Tomi, Heiskanen Jarkko, Leskinen Tuija, Meng Yaxing, Pasanen Jesse, Rovio Suvi, Koskinen Juhani S, Mykkänen Juha, Heinonen Olli J, Viikari Jorma, Rönnemaa Tapani, Niinikoski Harri, Raitakari Olli, Stenholm Sari, Pahkala Katja

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Pain control in neonates is crucial as inadequate management may impair neuronal development. Dexmedetomidine (DEX), an alpha2 agonist, is approved for intravenous use in ventilated neonates. While intranasal DEX is off-label in neonates and children, studies show its efficacy for magnetic resonance imaging sedation. Limited pharmacokinetic data exist for intranasal DEX in pre-term infants and neonates. This study aimed to develop an analytical method for DEX quantification in blood samples (20 μL) of complex patients collected with microsampling technique to enable future pharmacokinetic studies.

METHODS

A liquid-liquid extraction from blood absorbed in microsampling devices (MITRA) and an LC-MS/MS method were developed and validated following EMA/FDA guidelines. The method's suitability was verified by comparing results from nine paediatric blood samples collected in EDTA tubes or using MITRA devices.

RESULTS

All results obtained for selectivity (no interference at RT of DEX), sensitivity (DEX LLOQ = 0.025 ng/mL), linearity (R2 > 0.99), intra and inter-day repeatability (CV % 1.8-11.8), stability, and hematocrit effect met the acceptance criteria for bioanalytical method validation. Compared with plasma samples, the proposed method showed good consistency in detecting DEX in MITRA samples.

CONCLUSION

The MITRA microsampling tools reduce the amount of blood needed and the risks of anemisation for neonates hospitalised and simplifies procedures, allowing a reduction of the staff involved in the routine. The analytical and clinical validation of the method demonstrated its suitability to quantify DEX in a range of concentrations potentially useful for pharmacokinetic studies in paediatric patients for approval use and drug monitoring.

Для цитирования: Suorsa Kristin, Laitinen Tomi, Heiskanen Jarkko, Leskinen Tuija, Meng Yaxing, Pasanen Jesse, Rovio Suvi, Koskinen Juhani S, Mykkänen Juha, Heinonen Olli J, Viikari Jorma, Rönnemaa Tapani, Niinikoski Harri, Raitakari Olli, Stenholm Sari, Pahkala Katja. Device-Measured 24-h Movement Behaviors and Arterial Intima-Media Thickness in Young Adults.. Scandinavian journal of medicine & science in sports. 2026. DOI: 10.1111/sms.70387.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.