DOI 10.1016/j.ijrobp.2026.07.062
Multimodel RBE and Dose-Averaged LET Optimized Carbon Ion Radiation Therapy for Sacral Chordoma: Results of the First Year of Clinical Application.
Аннотация
PURPOSE: Carbon ion therapy (CIRT) optimization, driven by purely dosimetric and single-relative biological effectiveness (RBE) model may result in suboptimal solutions, particularly when considering dose-averaged LET (LETd) within the tumor. This study reports on the early outcomes of a clinical optimization strategy combining compliance with multi-RBE and explicit LETd escalation in a cohort of 10 patients with sacral chordoma treated with CIRT.
METHODS AND MATERIALS: Treatment plans, optimized with dosimetric objectives to a prescribed RBE-weighted dose (DRBE) of 73.6 Gy(RBE), using the local effect model (LEM) (Plan-D), served as the benchmark. The proposed strategy consisted of 3 steps: (1) plan optimization using the microdosimetric kinetic model (MKM) to 67.2 Gy(RBE); (2) iterative LEM-based recalculation to obtain plans compliant with RBE models; (3) inclusion of a cost-function term on the minimum LETd (LETd-min) to the gross tumor volume (GTV) (plan-L). The selected LETd-min ensured compliance with clinical goals under both nominal and robust scenarios. Plan-D and Plan-L were compared using variations in DRBE, LEM and MKM, and LETd to target volume percentages. Re-evaluation computed tomographies assessed interfraction robustness. Paired comparisons used the Wilcoxon signed-rank test. Acute toxicity was evaluated during treatment and at early follow-up.
RESULTS
The median GTV volume was 171.1 cc (90.6-636.7). The median LETd-min constraint applied was 44 keV/μm (range, 40-48). The median GTV LETd-98% increase was 29.2%, from 32.9 keV/μm (Plan-D) to 42.5 keV/μm (Plan-L). LEM-based dose deviations were not clinically relevant, while Plan-L showed significantly improved MKM dose homogeneity compared with Plan-D. Interfraction robustness of target coverage was comparable for both dose and LETd metrics, with deviations below 2% relative to the nominal plan. The early toxicity profile was clinically acceptable.
CONCLUSIONS
This study supports the feasibility of a novel optimization strategy for CIRT in large sacral chordomas, based on the synergistic maximization of dose, RBE, and LETd within the target, with acceptable robustness and well-tolerated acute toxicity in this initial patient series.