OBJECTIVE
To investigate rectal hydrogel spacer use, placement complications, and associated radiation delays in the United States.
METHODS
The Merative MarketScan Database was used to identify prostate cancer patients undergoing spacer placement or radiation alone between 2016 and 2021. Genitourinary and gastrointestinal complications and subsequent interventions that occurred after spacer placement but before radiation were captured. A 6-month window preceding spacer placement was employed to eliminate underlying diagnoses present before spacer placement. Delays in starting radiation after spacer placement were identified and categorized as more than 1, 2, or 3 months. A Cox proportional hazards model with a time-varying covariate of acute complications was used to assess the effect of complications on time-to-radiation.
RESULTS
We captured 3,732 spacer placements, of which 3,650 (97.8%) underwent radiation. The use of spacers among prostate cancer radiation patients increased from 0.5% in 2016 to 25.7% in 2021. Stereotactic body radiotherapy (SBRT) patients had the highest spacer use at 50.0% in 2021. Complications occurred in 6.4% (n = 235) of patients before starting radiation. Of these, 5.2% (n = 190) were genitourinary and 1.2% (n = 43) were gastrointestinal complications. Catheterization, cystoscopy, rectal endoscopy, and rectal abscess drainage were required for 21 (0.6%), 15 (0.4%), 12 (0.3%), 1 (0.03%), and 1 (0.03%) patients, respectively. Following a complication, patients had a significantly lower risk (Hazard Ratio 0.75, 95% CI 0.66-0.86, P <.001) of starting radiation compared to before the complication.
CONCLUSION
Rectal spacer use is prevalent amongst patients undergoing SBRT. While rare, spacer placement complications occur, which can delay the start of radiation therapy.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.