MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/00016489.2022.2050806

Медицинская библиотека · Acta oto-laryngologica · 2022

Clinical application of MIIRMR as a salvage method in gadolinium-enhanced MRI after intra-tympanic injection.

Huang Jianjian, Tang Cheng, Xia Wei, Feng Yiwei, Tan Songhua, Xie Lihong, Jiang Muliang, Qin Yuhong, Zhang Huiting, Tang Anzhou

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Three-dimensional fluid-attenuated inversion-recovery (3 D-FLAIR) and real inversion-recovery (3 D-real IR) sequences are used to detect endolymphatic hydrops (EH), but medium inversion-time inversion-recovery imaging with magnitude reconstruction (MIIRMR) may be more sensitive.

AIMS: We investigated the inner-ear visualisation success rate and EH detection rates of 3 D-FLAIR and 3 D-real IR, and whether salvage MIIRMR could improve EH detection.

MATERIALS AND

METHODS

Fifty-one patients (102 ears) with episodic or chronic vestibular syndrome were injected intra-tympanically with 8-fold diluted gadolinium, and 3 D-FLAIR and 3 D-real IR images obtained 24-h post-injection. If 3 D-FLAIR inner-ear visualisation failed, additional MIIRMR was performed. The success and EH detection rate increase by MIIRMR was calculated. The diagnostic performance of combined MIIRMR + 3D-FLAIR + 3D-real IR for Meniere's disease (MD) was evaluated.

RESULTS

The success rates of 3 D-FLAIR and 3 D-real IR were 88.90% and 72.55%, respectively. MIIRMR increased the success and EH detection rates by 11.10% and 6.86%, respectively. In MD, MIIRMR increased these rates by 10.53% and 10.53%, respectively. 3 D-FLAIR + 3D-real IR + MIIRMR had 92.11% sensitivity, 79.68% specificity, 72.92% positive-predictive value, and 94.44% negative-predictive value for MD diagnosis.

CONCLUSION AND SIGNIFICANCE: MIIRMR can improve success and EH detection rates when 3 D-FLAIR fails. Combined MIIRMR + 3D-FLAIR + 3D-real IR is more valuable for diagnosing MD than conventional sequences.

Для цитирования: Huang Jianjian, Tang Cheng, Xia Wei, Feng Yiwei, Tan Songhua, Xie Lihong, Jiang Muliang, Qin Yuhong, Zhang Huiting, Tang Anzhou. Clinical application of MIIRMR as a salvage method in gadolinium-enhanced MRI after intra-tympanic injection.. Acta oto-laryngologica. 2022. DOI: 10.1080/00016489.2022.2050806.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.