MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/s26165105

Медицинская библиотека · Sensors (Basel, Switzerland) · 2026

Concurrent Validity and Between-System Agreement of a Commercial Wearable Inertial Sensor System for Gait and Postural Sway Assessment in Progressive Supranuclear Palsy.

Novotny Ryan E, You Victor S, Hogen Cecilia A, Whitwell Jennifer L, Josephs Keith A, Kaufman Kenton R, Ali Farwa

СтатьяПеревод в очереди

Аннотация

Wearable inertial measurement units (IMUs) offer an accessible alternative to optical motion capture (MoCap) gait analysis, but their performance in Progressive Supranuclear Palsy (PSP) requires validation. We assessed the concurrent validity of IMU-derived versus MoCap-derived gait metrics and static postural sway in 30 patients with PSP using Bland-Altman analysis, Intraclass Correlation Coefficients (ICC), and Spearman rank correlations. Finally, we assessed equivalence using the Two one-sided tests (TOST) procedure. Multivariable linear regression was used to determine whether clinical severity, as measured by the PSP Rating Scale (PSPRS), independently predicted absolute IMU measurement error while controlling for patient age and gait velocity. IMUs demonstrated excellent between-system agreement for parameters such as cadence (100.76 ± 11.42 vs. 100.52 ± 11.59) and cycle time (1.21 ± 0.15 vs. 1.22 ± 0.15; ICC > 0.98), despite a systematic underestimation of gait velocity (p < 0.05). Agreement significantly diminished for micro-phases (e.g., single/double support times) and spatial asymmetry. Interestingly, the TOST procedure revealed that only sagittal and transverse trunk kinematics were equivalent between systems, with all other measures failing to find equivalency. For static sway, the IMU demonstrated strong rank-order correspondence for tracking relative postural instability (ρ = 0.82, p < 0.05). Multivariable analysis revealed that higher PSPRS scores are independently associated with greater between-system discrepancies in support phases and pelvic and trunk kinematics (p < 0.05), irrespective of reduced gait speed. These findings highlight the need to develop disease-specific algorithms, rather than relying on normative commercial models, to establish reliable digital biomarkers for monitoring progressive motor decline.

Для цитирования: Novotny Ryan E, You Victor S, Hogen Cecilia A, Whitwell Jennifer L, Josephs Keith A, Kaufman Kenton R, Ali Farwa. Concurrent Validity and Between-System Agreement of a Commercial Wearable Inertial Sensor System for Gait and Postural Sway Assessment in Progressive Supranuclear Palsy.. Sensors (Basel, Switzerland). 2026. DOI: 10.3390/s26165105.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.