Pediatric cardiology · 2025
Feasibility of Self-Expanding Transcatheter Pulmonary Valves in Patients with Pyramidal RVOT: Favorable Mid-term Outcomes.
СтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Zhu Wenhao, Xia Zhiyuan, Chan Jeffery Shi Kai, Wan Junyi, Xu Liang, Li Yihang, Zhang Jingnan, Tse Gary, Fang Fang, Zhang Gejun
Аннотация
Transcatheter pulmonary valve replacement (TPVR) is effective for treating significant pulmonary regurgitation (PR), but mid-term data in patients with pyramidal right ventricular outflow tract (RVOT) anatomy are limited. This multi-center retrospective study included patients who underwent TPVR between May 2014 and September 2023. Baseline and echocardiographic data were compared between patients with pyramidal and non-pyramidal RVOT. The primary endpoint was peri-procedural device success, defined as technical success, optimal valve function on discharge echocardiography (RVOT gradient < 30 mmHg, less than moderate PR, no significant paravalvular leak), and absence of in-hospital mortality or re-intervention. The secondary endpoint was 1-year freedom from all-cause mortality, cardiac hospitalization, endocarditis, significant stent fracture, valve dysfunction, and device-related re-intervention. Sixty-eight patients were enrolled. Device success was achieved in 86.7% of pyramidal RVOT patients and 100% of non-pyramidal patients (P = 0.067). At 1 year, no significant difference was observed in the composite secondary endpoint (91.7% vs. 86.0%, P = 0.605). Both groups showed similar improvements in echocardiographic and clinical outcomes. Additionally, no statistically significant differences were observed between the two groups regarding post-TPVR regurgitation and paravalvular leakage. TPVR using self-expanding valves in pyramidal RVOT showed acceptable device success rates and favorable mid-term outcomes in both clinical and hemodynamic parameters. Morphology-based pre-procedural planning is essential for optimizing results.
Предметные рубрики MeSH
HumansMaleFemaleRetrospective StudiesPulmonary Valve InsufficiencyPulmonary ValveEchocardiographyTreatment OutcomeCardiac CatheterizationFeasibility StudiesChild, PreschoolChildHeart Valve Prosthesis ImplantationHeart Valve ProsthesisInfantAdolescentProsthesis DesignFollow-Up StudiesHeart Ventricles