MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/03000605211060980

Медицинская библиотека · The Journal of international medical research · 2021

Endoscopy-guided in vivo evaluation of ciliary sulcus location in children with ectopia lentis.

Yang Jing, Wang Zhirong, Cao Qianzhong, Wang Yiyao, Wu Jieyi, Lian Zhangkai, Zheng Danying

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To assess a new method to measure the distance of the needle passage from the ciliary sulcus to the corneal limbus anterior border (CTC) in eyes with ectopia lentis directly in vivo via endoscopy and to further evaluate the correlations among the CTC, age, automated horizontal white-to-white distance (WTW), and ocular axial length (AL).

METHODS

The WTW and AL were measured using an optical biometer. An intraocular endoscope was used during transscleral suture fixation of posterior chamber intraocular lenses to identify the true location of the ciliary sulcus. Linear regression analysis was used to assess the correlation between the CTC and other ocular biological parameters, including age, WTW, and AL.

RESULTS

Thirty eyes of 30 children with ectopia lentis were evaluated. A statistically significant correlation was found between age and the CTC. The CTC could be predicted by the equation CTC = 0.1313 × Age + 0.9666. No statistically significant correlations were found between CTC and WTW, CTC and AL, WTW and AL, or WTW and age.

CONCLUSION

Endoscopy is useful for precisely suturing intraocular lens haptics in the real ciliary sulcus. Age can be used as an equivalent parameter for prediction of the true ciliary sulcus location.

Для цитирования: Yang Jing, Wang Zhirong, Cao Qianzhong, Wang Yiyao, Wu Jieyi, Lian Zhangkai, Zheng Danying. Endoscopy-guided in vivo evaluation of ciliary sulcus location in children with ectopia lentis.. The Journal of international medical research. 2021. DOI: 10.1177/03000605211060980.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.