Local lymph node assay with non-radioisotope alternative endpoints.

Suda Akiko, Yamashita Masahiro, Tabei Mitsuyuki, Taguchi Kazuhiko, Vohr Hans-Werner, Tsutsui Naohisa, Suzuki Ritsuyoshi, Kikuchi Katsuaki, Sakaguchi Keisuke, Mochizuki Kouki, Nakamura Kazuichi

Сравнительное исследованиеОценочное исследованиеСтатьяПеревод в очереди

Аннотация

The local lymph node assay has recently been accepted by regulatory agencies as a stand-alone alternate method for predicting allergic contact dermatitis. To compare the sensitivity of non-radioisotope methods with that of the standard assay, we determined if these modified methods would affect evaluation of sensitization potency. For this reason, we used 2,4-dinitrochlorobenzene (DNCB) and benzocaine for different sensitizing criteria. Female CBA mice were treated for 3 days with a test compound or vehicle applied to each side of both ears. Bilateral auricular lymph node proliferative activity was assessed by the following endpoints with incorporation of 3H-methyl thymidine (3H-TdR), bromodeoxyuridine (BrdU) in vivo, and BrdU ex vivo, IL-2 production, and proliferating cell nuclear antigen (PCNA) expression. Ear thickness was also tested. The strong sensitizer DNCB was detectable by any of the non-radioisotope endpoints as well as by radioisotope-dependent standard assay. On the other hand, when evaluating the weak sensitizer benzocaine, significant changes were evident in BrdU incorporation ex vivo and in vivo, and IL-2 production. We believe that these non-radioisotope methods can assess allergic contact dermatitis caused by chemicals even in the laboratory, where it can be difficult to handle radioisotopes.

Для цитирования: Suda Akiko, Yamashita Masahiro, Tabei Mitsuyuki, Taguchi Kazuhiko, Vohr Hans-Werner, Tsutsui Naohisa, Suzuki Ritsuyoshi, Kikuchi Katsuaki, Sakaguchi Keisuke, Mochizuki Kouki, Nakamura Kazuichi. Local lymph node assay with non-radioisotope alternative endpoints.. The Journal of toxicological sciences. 2002. DOI: 10.2131/jts.27.205.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.