MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41433-021-01880-9

Медицинская библиотека · Eye (London, England) · 2022

Real world outcomes of sutureless and glueless sclerally fixated intraocular lens implantation.

Gajula Shruthi, Manayath George J, Verghese Shishir, Saravanan V R, Narendran Kalpana, Narendran Venkatapathy

СтатьяПеревод в очереди

Аннотация

PURPOSE: To report the outcomes of sutureless intrascleral fixation of a 3-piece intraocular lens in the ciliary sulcus, in a large cohort of patients with aphakia of various aetiology

METHODS

Retrospective, non-comparative, single centre interventional study of 250 aphakic eyes of various causes, which underwent sutureless and glueless intrascleral fixation of 3-piece intraocular lens (IOL). All patients were required to have at least 3 months of follow up post procedure to be included in the study. Anatomical and functional outcomes obtained were statistically analysed for significance.

RESULTS

A total of 250 eyes of 246 patients were included in the study population. The average age was 56.5 years ± 16.4 (range 6-86 years). The mean best-corrected visual acuity (BCVA) significantly improved from 0.74 ± 0.6 logMAR (approx. Snellen equivalent 20/110) to 0.48 ± 0.36 logMAR (approx. Snellen equivalent 20/60), (p < 0.001) following surgery. Early postoperative complication (<2 weeks) included hypotony (n = 10, 4%), ocular hypertension (n = 38,15.2%) and vitreous haemorrhage (n = 50, 20%). Late complications included retinal detachment (n = 14, 5.6%%), cystoid macular oedema (n = 24, 9.6%), scleral erosion (n = 1, 0.4%), haptic extrusion to subconjunctival space (n = 3, 1.2%) and IOL subluxation or dislocation (n = 5, 2%)

CONCLUSION

This cost-effective and easier technique of sutureless scleral fixated 3-piece IOL implantation provided good visual acuity outcomes in a large cohort of patients and was well tolerated.

Для цитирования: Gajula Shruthi, Manayath George J, Verghese Shishir, Saravanan V R, Narendran Kalpana, Narendran Venkatapathy. Real world outcomes of sutureless and glueless sclerally fixated intraocular lens implantation.. Eye (London, England). 2022. DOI: 10.1038/s41433-021-01880-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.