DOI 10.1136/bjophthalmol-2011-300248
Retinal haemorrhage description tool.
Аннотация
BACKGROUND
Retinal haemorrhages are an important finding in children with abusive and accidental head trauma. There are no standardised and validated protocols to describe them in a consistent manner. The aim of this web-based study was to establish the reliability and validity of a new retinal haemorrhage description tool.
MATERIALS AND METHOD: Our tool is a comprehensive questionnaire, which is applied using a retinal schematic that divides the retina into four independent zones. Four independent observers scored retinal haemorrhages from 80 retinal photographs. Inter- and intra-rater agreement (by repeat assessment of 10 photographs for each examiner) were calculated using Fleiss κ statistics.
RESULTS
A high inter-rater agreement was noted for haemorrhages in the peripapillary zones, whereas agreement was only fair for all other zones. Intra-rater agreement was high only for the posterior pole. Photographs may be an unreliable way of documenting retinal haemorrhages particularly from the peripheral retina, thus underscoring the importance of a thorough clinical examination.
CONCLUSION
This study shows that the tool achieves some validity for describing haemorrhages in the posterior retina. It performs less well in the peripheral zones.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.