Evaluation of a Hirschberg Test-Based Application for Measuring Ocular Alignment and Detecting Strabismus.

Garcia Stephanie Suzanne S, Santiago Alvina Pauline D, Directo Princess Mae C

СтатьяПеревод в очереди

Аннотация

Purpose: Photographic Hirschberg test applications are practical options for screening in areas where a specialist is not available. A semi-automated Hirschberg test-based application was developed and evaluated on its ability to detect and measure strabismus at distance and near fixation.

Methods

This is a prospective cross-sectional inter-rater agreement study conducted at a tertiary hospital. Study A evaluated the ability of the application to determine the presence or absence of strabismus in subjects of unknown strabismus status (n = 28). Study B evaluated the ability of the application to measure the deviation of strabismic subjects (n = 8). All subjects underwent alternate prism cover test (APCT) at distance and near fixation. Facial photographs at distance and near fixation were taken. Each photograph underwent automated face and eye detection, manual limbus and corneal reflex identification, and strabismus detection and measurement.

Results

The application obtained a matching rate of 95.14% for the face and eyes. The application yielded a sensitivity of 92.86% for horizontal strabismus at distance and near fixation, however, with low specificity values (7.692%, 14.81%, and 8%). The Bland-Altman plots derived from Study B showed bias values of application measurements between 3.625Δ and 6.125Δ with wide intervals of the limits of agreement. Repeatability of the measurements yielded bias values of -0.625Δ and 2.5Δ for horizontal and vertical strabismus at distance and 4.375Δ and 1.25Δ at near fixation, respectively.

Conclusion

This semi-automated Hirschberg test-based application can effectively determine the face and eye location and shows potential as a screening tool for horizontal strabismus.

Для цитирования: Garcia Stephanie Suzanne S, Santiago Alvina Pauline D, Directo Princess Mae C. Evaluation of a Hirschberg Test-Based Application for Measuring Ocular Alignment and Detecting Strabismus.. Current eye research. 2021. DOI: 10.1080/02713683.2021.1916038.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.