MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/bjo-2023-324488

Медицинская библиотека · The British journal of ophthalmology · 2024

Deep learning model for extensive smartphone-based diagnosis and triage of cataracts and multiple corneal diseases.

Ueno Yuta, Oda Masahiro, Yamaguchi Takefumi, Fukuoka Hideki, Nejima Ryohei, Kitaguchi Yoshiyuki, Miyake Masahiro, Akiyama Masato, Miyata Kazunori, Kashiwagi Kenji, Maeda Naoyuki, Shimazaki Jun, Noma Hisashi, Mori Kensaku, Oshika Tetsuro

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

AIM: To develop an artificial intelligence (AI) algorithm that diagnoses cataracts/corneal diseases from multiple conditions using smartphone images.

METHODS

This study included 6442 images that were captured using a slit-lamp microscope (6106 images) and smartphone (336 images). An AI algorithm was developed based on slit-lamp images to differentiate 36 major diseases (cataracts and corneal diseases) into 9 categories. To validate the AI model, smartphone images were used for the testing dataset. We evaluated AI performance that included sensitivity, specificity and receiver operating characteristic (ROC) curve for the diagnosis and triage of the diseases.

RESULTS

The AI algorithm achieved an area under the ROC curve of 0.998 (95% CI, 0.992 to 0.999) for normal eyes, 0.986 (95% CI, 0.978 to 0.997) for infectious keratitis, 0.960 (95% CI, 0.925 to 0.994) for immunological keratitis, 0.987 (95% CI, 0.978 to 0.996) for cornea scars, 0.997 (95% CI, 0.992 to 1.000) for ocular surface tumours, 0.993 (95% CI, 0.984 to 1.000) for corneal deposits, 1.000 (95% CI, 1.000 to 1.000) for acute angle-closure glaucoma, 0.992 (95% CI, 0.985 to 0.999) for cataracts and 0.993 (95% CI, 0.985 to 1.000) for bullous keratopathy. The triage of referral suggestion using the smartphone images exhibited high performance, in which the sensitivity and specificity were 1.00 (95% CI, 0.478 to 1.00) and 1.00 (95% CI, 0.976 to 1.000) for 'urgent', 0.867 (95% CI, 0.683 to 0.962) and 1.00 (95% CI, 0.971 to 1.000) for 'semi-urgent', 0.853 (95% CI, 0.689 to 0.950) and 0.983 (95% CI, 0.942 to 0.998) for 'routine' and 1.00 (95% CI, 0.958 to 1.00) and 0.896 (95% CI, 0.797 to 0.957) for 'observation', respectively.

CONCLUSIONS

The AI system achieved promising performance in the diagnosis of cataracts and corneal diseases.

Для цитирования: Ueno Yuta, Oda Masahiro, Yamaguchi Takefumi, Fukuoka Hideki, Nejima Ryohei, Kitaguchi Yoshiyuki, Miyake Masahiro, Akiyama Masato, Miyata Kazunori, Kashiwagi Kenji, Maeda Naoyuki, Shimazaki Jun, Noma Hisashi, Mori Kensaku, Oshika Tetsuro. Deep learning model for extensive smartphone-based diagnosis and triage of cataracts and multiple corneal diseases.. The British journal of ophthalmology. 2024. DOI: 10.1136/bjo-2023-324488.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.