m+Medelevator.RU
← Поиск публикаций
International journal of implant dentistry · 2024

Numerical study on the three-dimensional temperature distribution according to laser conditions in photothermal therapy of peri-implantitis.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Paik Jeeyong, Kim Donghyuk, Kim Hyunjung, Kim Hee-Sun

Аннотация

PURPOSE: Dental implants have been successfully implemented as a treatment for tooth loss. However, peri-implantitis, an inflammatory reaction owing to microbial deposition around the implant, can lead to implant failure. So, it is necessary to treat peri-implantitis. Therefore, this numerical study is aimed at investigating conditions for treating peri-implantitis.

METHODS: Photothermal therapy, a laser treatment method, utilizes photothermal effect, in which light is converted to heat. This technique has advantage of selectively curing inflamed tissues by increasing their temperature. Accordingly, herein, photothermal effect on peri-implantitis is studied through numerical analysis with using Arrhenius damage integral and Arrhenius thermal damage ratio.

RESULTS: Through numerical analysis on peri-implantitis treatment, we explored temperature changes under varied laser settings (laser power, radius, irradiation time). We obtained the temperature distribution on interface of artificial tooth root and inflammation and determined whether temperature exceeds or does not exceed 47℃ to know which laser power affects alveolar bone indirectly. We defined the Arrhenius thermal damage ratio as a variable and determined that the maximum laser power that does not exceed 47℃ at the AA' line is 1.0 W. Additionally, we found that the value of the Arrhenius thermal damage ratio is 0.26 for a laser irradiation time of 100 s and 0.50 for 500 s.

CONCLUSION: The result of this numerical study indicates that the Arrhenius thermal damage ratio can be used as a standard for determining the treatment conditions to help assisted laser treatment for peri-implantitis in each numerical analysis scenario.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты