Serial cardiac influence of volume overload induced by interventional therapy for central venous stenosis or occlusion in chronic hemodialysis patients.

Horita Yuki, Namura Masanobu, Ikeda Masatoshi, Tsuchiya Taketsugu, Terai Hidenobu, Fukuoka Ryota, Tama Naoto, Takagi Toshimitsu, Kumatani Yuji, Ishimori Yasuhiro

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

Upper arm swelling and venous hypertension at arteriovenous fistula sites, and insufficiency of hemodialysis are induced by central venous lesions in chronic hemodialysis patients. Percutaneous transluminal angioplasty (PTA) for central venous lesions is first-choice treatment. Cardiac function can be evaluated by measuring the acute increase in venous return volume after PTA.

METHODS

We studied 6 cases of successful PTA for central venous stenotic or occluded lesions, and evaluated cardiac function by Swan-Ganz (SG) catheter and ultrasound echocardiography (UCG) at pre-, post-PTA, and on the following day.

RESULTS

Ejection fraction (EF) in 6 cases was 71.0 ± 5.5% on UCG. Two cases of subclavian venous stenosis, one case of subclavian venous occlusion, and three cases of brachiocephalic venous occlusion were enrolled. The reference diameter (RD) was 10.2 ± 4.9 mm, % diameter-stenosis (%DS) was 92.2 ± 12.2% at pre-PTA, and %DS at post-PTA was 21.7 ± 20.7%. There were no significant differences in pulmonary capillary-wedge, pulmonary artery, and right ventricular end-diastolic pressure in SG at pre- and post-PTA. The pressure of right atrium (RA) and cardiac output (CO) were significantly increased by PTA (RA pressure at pre-/post-PTA, 9.7 ± 2.9/11.7 ± 3.6 mmHg, p<0.05, CO at pre-/post-PTA 5.09 ± 2.07/5.45 ± 2.25 l/min, p<0.05). There were no significant differences in serial EF, left atrial and left ventricular diameters on UCG. However, the short-diameter of right ventricle (RV) and RA were significantly increased at post-PTA and recovered on the following day (RV short-diameter at pre-/post-/following-day PTA, 26.7 ± 3.5/32.5 ± 1.9/29.1 ± 1.7 mm, p<0.05; RA short-diameter at pre-/post-/following-day PTA, 30.2 ± 4.2/36.3 ± 2.4/32.1 ± 3.6mm, p<0.05).

CONCLUSIONS

Volume overload after PTA for central venous stenotic or occluded lesions in chronic hemodialysis patients resulted in increased RA and RV diameters. These changes were transient and completely recovered by the following day. PTA for central venous lesions in patients with normal EF can be performed without clinical cardiac problems.

Для цитирования: Horita Yuki, Namura Masanobu, Ikeda Masatoshi, Tsuchiya Taketsugu, Terai Hidenobu, Fukuoka Ryota, Tama Naoto, Takagi Toshimitsu, Kumatani Yuji, Ishimori Yasuhiro. Serial cardiac influence of volume overload induced by interventional therapy for central venous stenosis or occlusion in chronic hemodialysis patients.. Journal of cardiology. 2011. DOI: 10.1016/j.jjcc.2011.01.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.