MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijporl.2022.111114

Медицинская библиотека · International journal of pediatric otorhinolaryngology · 2022

Early surgical and audiologic outcomes of active, transcutaneous, osseointegrated bone-conduction hearing device (Osia 2® system) placement.

Florentine Michelle M, Virbalas Jordan, Chan Dylan K

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To assess the outcomes of pediatric Osia 2® System placements.

METHODS

We performed a retrospective chart review of primary and revision Osia 2® System surgical cases at two tertiary academic children's hospitals. Operative details and post-operative surgical and audiologic outcomes were recorded.

RESULTS

18 cases were performed on 14 children (mean age: 11.5 years, range 7-16) and included 9 primary surgeries and 9 revisions from BAHA Attract®, Connect® and Sophono® implants. Surgical planning for revision surgeries was complex due to prior incisions, implants, and bony contour. Post-operative aided audiograms revealed pure tone average (0.5-4 kHz) of 26.2 ± 2.5 dB HL (mean ± SD), with no high frequency roll-off (8 kHz aided threshold: 23.8 ± 7.5 dB HL). Two minor post-operative complications were identified.

CONCLUSION

Bone-conduction hearing devices (BCHDs) are used to improve access to sound for children with conductive hearing loss, single-sided deafness, and aural atresia. Traditional passive, percutaneous abutment-based and transcutaneous magnet-based surgical BCHDs can be limited by skin complications and high-frequency acoustic attenuation. Recent availability of active, transcutaneous osseointegrated BCHD systems presents potential for improvement on both of these traditional limitations. Initial experience with the Osia 2® System demonstrates overall successful, uncomplicated placement with excellent audiologic outcomes. Revision cases require careful surgical planning. Further follow-up and comparative studies with other BCHDs are necessary to fully evaluate the effectiveness of the Osia 2® System.

Для цитирования: Florentine Michelle M, Virbalas Jordan, Chan Dylan K. Early surgical and audiologic outcomes of active, transcutaneous, osseointegrated bone-conduction hearing device (Osia 2® system) placement.. International journal of pediatric otorhinolaryngology. 2022. DOI: 10.1016/j.ijporl.2022.111114.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.