MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00405-022-07338-2

Медицинская библиотека · European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2022

Pediatric morphometric study to guide the optimized implantation of the Osia® 2 implant system.

Posta Balint, Perenyi Adam, Szabo Linda, Nagy Roland, Katona Gabor, Csakanyi Zsuzsanna, Rovo Laszlo, Bere Zsofia

СтатьяПеревод в очереди

Аннотация

PURPOSE: Continuous technological advances result in the availability of new bone conduction hearing implants, of which their suitability for pediatric patients is of major concern. The CochlearTMOsia® 2 is a new active osseointegrated steady-state implant system that uses digital piezoelectric stimulation to treat hearing loss. The implant in the United States was approved for patients aged 12 years and above, whereas the CE mark is independent of age, the only requirement is body weight of at least 7 kg. Therefore, further clinical studies are required to assess device characteristics in younger patients. The aim of our study was to perform a morphometric study among 5-12-year-old children, and to develop a surgical protocol for Osia 2 system implantation based on these findings.

METHODS

We examined retrospectively cranial CT scans of 5-12-year-old patients from our clinical database. We measured the bone and soft-tissue thickness in the region of interest, and the position of the sigmoid sinus. 3D printed temporal bones were also used for planning.

RESULTS

Soft-tissue thickness varied between 3.2 ± 0.5 mm and 3.6 ± 0.6 mm and bone thickness varied between 3.5 ± 1.1 mm and 4.7 ± 0.3 mm. The sigmoid sinus was located 1.3 ± 0.2 cm posterior to the ear canal, and the anterior distance was 4.8 ± 0.9 to 7.1 ± 1.1 mm.

CONCLUSIONS

Our morphometric studies showed that patients aged 5-12 have different anatomical dimensions compared to adults, but that implantation of the Osia 2 system is feasible in these patients using an altered implant positioning recommended by our data. The Cochlear™ Osia® 2 is, therefore, an option for hearing rehabilitation in younger pediatrics.

Для цитирования: Posta Balint, Perenyi Adam, Szabo Linda, Nagy Roland, Katona Gabor, Csakanyi Zsuzsanna, Rovo Laszlo, Bere Zsofia. Pediatric morphometric study to guide the optimized implantation of the Osia® 2 implant system.. European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery. 2022. DOI: 10.1007/s00405-022-07338-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.