Аннотация

PURPOSE: Most reports of strabismus after glaucoma drainage device implantation study larger devices and rarely note the incidence of strabismus after Ahmed glaucoma valve (AGV) implantation. It is unknown if the pattern of strabismus is similar with smaller devices. We investigated characteristics of strabismus after AGV implantation.

DESIGN

Retrospective review.

METHODS

Institutional study of 732 patients at our institution undergoing AGV implantation between 2013 and 2018. Rate and characteristics of strabismus were the primary outcome; age, gender, and location of AGVs were also analyzed.

RESULTS

We identified 29 patients who developed new-onset strabismus postoperatively after initial AGV implantation, for 4% incidence of strabismus. Twenty-one (72%) of these had diplopia. AGVs were implanted superotemporally in 21, superonasally in 5, inferotemporally in 1, and inferonasally in 2. Three patients were esotropic, 11 were exotropic, 4 had hypertropia, 2 had hypotropia, and 9 patients had combined horizontal/vertical strabismus (esotropia/hypotropia [n = 1] or exotropia/hypertropias [n = 8]). Exotropia was the most common type of strabismus in both the superotemporal and superonasal (60%) AGV groups. Superotemporal AGVs were more commonly associated with ipsilateral hypertropia (43%) than superonasal AGVs. Treatments included strabismus surgery (n = 14), prisms (n = 6), or an occlusive lens (n = 1).

DISCUSSION: In the largest single-center series of patients undergoing initial AGV implantation, the overall incidence of postoperative strabismus was 4%. This is comparable to strabismus incidence following implantation of other types of glaucoma drainage devices, even larger devices. The possibility of this complication should be discussed with patients prior to surgery.

Для цитирования: Robbins Laura, Goseki Toshiaki, Law Simon K, Nouri-Mahdavi Kouros, Caprioli Joseph, Coleman Anne L, Giaconi Joann A, Demer Joseph L, Velez Federico G, Pineles Stacy L. Strabismus After Ahmed Glaucoma Valve Implantation.. American journal of ophthalmology. 2020. DOI: 10.1016/j.ajo.2020.08.019.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.