MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-017-06462-y

Медицинская библиотека · Scientific reports · 2017

The Predictive Value of Genetic Analyses in the Diagnosis of Tetrahydrobiopterin (BH4)-Responsiveness in Chinese Phenylalanine Hydroxylase Deficiency Patients.

Zhu Tianwen, Ye Jun, Han Lianshu, Qiu Wenjuan, Zhang Huiwen, Liang Lili, Gu Xuefan

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Molecular characterization of PAH deficiency has been proven essential in establishing treatment options. We examine the diagnostic accuracy of two genetic assays to predict BH4 responsiveness: to determine whether the AV sum test or mutation-status assessment test can obviate the need for BH4 loading in Chinese patients. The overall predicted response in 346 patients was 31.65% by the AV sum test and 25.43% by the other assay; both percentages were lower than 51.06% derived from loading results in 94 patients. Responders were compound heterozygotes with definite BH4 responsive mutations, while non-responders had null/null ones; some consistently with specific mutations and genotypes. The sensitivity and specificity of the assays were 81.1% and 92.5% for the AV sum, and 82.9%, 97.3% for the other. An AV sum cutoff >2 has a positive predictive value (PPV) of 90.9%, while the presence of at least one BH4 responsive mutation has a PPV of 97.1%. The two approaches showed good concordance. Our data confirmed that the mutation-status assessment has a higher diagnostic accuracy in predicting response for Chinese patients than the AV sum test. BH4-responsiveness may be predicted or excluded from patients' molecular characteristics to some extent, thus some patients may avoid the initial loading.

Для цитирования: Zhu Tianwen, Ye Jun, Han Lianshu, Qiu Wenjuan, Zhang Huiwen, Liang Lili, Gu Xuefan. The Predictive Value of Genetic Analyses in the Diagnosis of Tetrahydrobiopterin (BH4)-Responsiveness in Chinese Phenylalanine Hydroxylase Deficiency Patients.. Scientific reports. 2017. DOI: 10.1038/s41598-017-06462-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.