MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s40618-026-02874-8

Медицинская библиотека · Journal of endocrinological investigation · 2026

Novel biomarkers to guide glucocorticoid replacement in primary adrenal insufficiency: a proof-of-concept study using copeptin-derived ratios.

Bima Chiara, Campioni Lorenzo, Berton Alessandro Maria, Sola Chiara, Bergoglio Beatrice, Di Carlo Maria Chiara, Ponzetto Federico, Settanni Fabio, Ceccato Filippo, Parasiliti-Caprino Mirko, Giordano Roberta

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Optimising glucocorticoid (GC) replacement in primary adrenal insufficiency (PAI) remains challenging, as clinical and biochemical markers do not reliably mirror tissue cortisol exposure.

OBJECTIVE

To evaluate salivary cortisone exposure and copeptin-derived ratios as candidate biomarkers of GC replacement adequacy in PAI.

DESIGN

Cross-sectional case-control study with 12-month follow-up including nineteen adults with autoimmune or idiopathic PAI on stable hydrocortisone (HC; immediate- or dual-release) plus fludrocortisone, and forty-three healthy controls.

METHODS

Six daytime saliva samples were collected for cortisol and cortisone quantification by LC-MS/MS. The area-under-the-curve (AUC) of cortisone was computed, and patients were classified as GC excess (AUC above the 90th percentile of controls; Group A) or adequate replacement (10th-90th percentile; Group B). Plasma ACTH, copeptin, renin, electrolytes and osmolarity were measured fasting and 120 min post-dose.

RESULTS

At baseline, 31.6% of patients showed GC excess, increasing to 36.8% at follow-up. Compared with Group B, Group A exhibited higher HbA1c (46.5 vs. 34.0 mmol/mol, p < 0.05) and diastolic blood pressure (84.5 ± 8.7 vs. 77.0 ± 9.6 mmHg, p < 0.05) with lower pulse pressure. ACTH and ACTH/copeptin ratios were markedly reduced in Group A both fasting (median 38.1 vs. 132.4) and post-dose (12.9 vs. 41.6), while renin/copeptin ratios declined at T1. ACTH/copeptin correlated inversely with cortisone AUC (r = - 0.59, p < 0.01).

CONCLUSIONS

Salivary cortisone AUC, together with ACTH/copeptin and renin/copeptin ratios, identifies physiologically distinct GC exposure profiles linked to metabolic and haemodynamic alterations. These biomarkers may refine personalised GC replacement in PAI.

Для цитирования: Bima Chiara, Campioni Lorenzo, Berton Alessandro Maria, Sola Chiara, Bergoglio Beatrice, Di Carlo Maria Chiara, Ponzetto Federico, Settanni Fabio, Ceccato Filippo, Parasiliti-Caprino Mirko, Giordano Roberta. Novel biomarkers to guide glucocorticoid replacement in primary adrenal insufficiency: a proof-of-concept study using copeptin-derived ratios.. Journal of endocrinological investigation. 2026. DOI: 10.1007/s40618-026-02874-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.