BACKGROUND

Transcranial Doppler ultrasonography (TCD) and near-infrared spectroscopy (NIRS) are indirect measures of neurovascular coupling (NVC). No studies have assessed the feasibility of an integrated TCD-NIRS approach to measure NVC in patients with dementia, delirium, and depression.

NEW METHOD: TCD-NIRS was trialled in 10 healthy volunteers, 11 patients with depression, 8 with dementia, and 5 with delirium. Participants underwent continuous cerebral blood velocity measurements, measured from the dominant middle cerebral artery (MCAv) and non-dominant posterior cerebral artery (PCAv), at rest and in response to four cognitive tasks. Heart rate (HR), end-tidal carbon dioxide (EtCO2), blood pressure (BP), prefrontal oxygenated (HbO2) and deoxygenated (HbR) haemoglobin levels were measured.

RESULTS

Resting mean MCAv differed significantly between groups (healthy volunteers: 53.9 (SD=8.09) cm/s, depression: 41.9 (9.31) cm/s (p = 0.041), dementia: 42.5 (13.7) cm/s, (0.150) delirium: 32.6 (7.48) cm/s (p = 0.002), after correction for age and BP (p = 0.012). There were no significant differences in resting PCAv, BP, EtCO2, HR, or prefrontal oxygenation. Participants with delirium were unable to complete the task-activated section of the protocol. All four tasks evoked indirect changes in NVC in healthy volunteers, and in patients with depression and dementia; only HbR differed in the depression group relative to the dementia group (p = 0.021).

COMPARISON WITH EXISTING

METHODS

While these techniques have been used individually in the different patient groups, they have not been used in conjunction to assess differences in NVC between all three groups.

CONCLUSIONS

An integrated TCD-NIRS protocol in this pilot study was feasible in these patient groups to measure NVC, but not in delirium.

Для цитирования: Edwards Olivia, Nicholls Jennifer K, Desai Bhavisha, Panerai Ronney B, Ball James D, Sensier Yvonne, Mukaetova-Ladinska Elizabeta, Beishon Lucy. Feasibility of integrated transcranial doppler ultrasound-near-infrared spectroscopy to measure cerebral haemodynamics in dementia, delirium, and depression (the VESPAR Project): A pilot study.. Journal of neuroscience methods. 2026. DOI: 10.1016/j.jneumeth.2026.110784.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.