MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/ijo.ijo_703_18

Медицинская библиотека · Indian journal of ophthalmology · 2019

Clinical and electrophysiological results of eye muscle surgery in 17 patients with downbeat nystagmus.

Hertle Richard W, Ahmad Ashraf

СтатьяПеревод в очереди

Аннотация

PURPOSE: To test the hypothesis that eye muscle surgery in treatment of patients with acquired downbeat nystagmus results in improvement measures of visual and ocular motor function.

METHODS

This is a prospective, interventional case series analysis of clinical and electrophyisological data before and after eye muscle surgery in 17 patients with acquired downbeat nystagmus who did not respond to medical treatments. Outcome measures included: 1) routine demography and clinical characteristics, 2) subjective oscillopsia (SO), 3) binocular best-corrected visual acuity in the null position (BVA), 3) primary position strabismic deviation (SD), 5) anomalous head posture (AHP), 6) contrast sensitivity function (CS), and 7) nystagmus slow phase velocity (SPV). All patients were followed at least 12 months. Parametric and non-parametric statistical analysis of outcome measure data above pre- and post-treatment were perfomed using standard software on grouped data using computerized software.

RESULTS

Patients' age ranged from 5 to 85 years (average 27 years). About 59% were male. Follow up ranged from 1-10 years (average 2.0 years). Around 70% had an associated central nervous systemic diagnosis, 100% had an AHP, oscillopsia and decreased CS, 53% had other eye disease, and 59% had strabismus. There were no complications from surgery. There were signficant post-treatment improvements in mean/median group BVA, SO, SD, AHP, CS, and SPV.

CONCLUSION

This study supports the hypothesis that eye muscle surgery as treatments for patients with acquired downbeat nystagmus can result in improvements in multiple aspects of ocular motor and visual functions.

Для цитирования: Hertle Richard W, Ahmad Ashraf. Clinical and electrophysiological results of eye muscle surgery in 17 patients with downbeat nystagmus.. Indian journal of ophthalmology. 2019. DOI: 10.4103/ijo.ijo_703_18.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.