DOI 10.36660/abc.20230585

Медицинская библиотека · Arquivos brasileiros de cardiologia · 2024

Long-Term Effects of Pulmonary Valve Implantation and Prosthesis Evolution in Patients with Repaired Tetralogy of Fallot.

Caneo Luiz Fernando, Turquetto Aida Luiza Ribeiro, Boschiero Matheus Negri, Amato Luciana Patrick, Ishikawa Walther Yoshiharu, Hodas Fabiana Padilha, Ligeiro Melissa Ganeko, Agostinho Daniela Regina, Miana Leonardo Augusto, Tanamati Carla, Gonçalves Rilvani Cavalcante, Penha Juliano Gomes, Massoti Maria Raquel Brigoni, Jatene Marcelo Biscegli, Jatene Fabio Biscegli

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Pulmonary valve regurgitation is a significant long-term complication in patients with tetralogy of Fallot (TOF).

OBJECTIVE

This study aims to investigate the effects of pulmonary valve implantation (PVI) on the anatomy and function of the right ventricle (RV) and the long-term evolution of the implanted prosthesis in the pulmonary position.

METHODS

A single-center retrospective cohort analysis was performed in 56 consecutive patients with TOF who underwent PVI. The study included patients of both sexes, aged ≥ 12 years, and involved assessing clinical and surgical data, pre- and post-operative cardiovascular magnetic resonance imaging, and echocardiogram data more than 1 year after PVI.

RESULTS

After PVI, there was a significant decrease in RV end-systolic volume indexed by body surface area (BSA), from 89 mL/BSA to 69 mL/BSA (p < 0.001) and indexed RV end-diastolic volume, from 157 mL/BSA to 116 mL/BSA (p < 0.001). Moreover, there was an increase in corrected RV ejection fraction [ RVEFC = net pulmonary flow (pulmonary forward flow - regurgitant flow) / R V end-diastolic volume ] from 23% to 35% (p < 0.001) and left ventricular ejection fraction from 58% to 60% (p = 0.008). However, a progressive increase in the peak pulmonary valve gradient was observed over time, with 25% of patients experiencing a gradient exceeding 60 mmHg. Smaller prostheses (sizes 19 to 23) were associated with a 4.3-fold higher risk of a gradient > 60 mmHg compared to larger prostheses (sizes 25 to 27; p = 0.029; confidence interval: 1.18 to 17.8).

CONCLUSION

As expected, PVI demonstrated improvements in RV volumes and function. Long-term follow-up and surveillance are crucial for assessing the durability of the prosthesis and detecting potential complications. Proper sizing of prostheses is essential for improved prosthesis longevity.

Для цитирования: Caneo Luiz Fernando, Turquetto Aida Luiza Ribeiro, Boschiero Matheus Negri, Amato Luciana Patrick, Ishikawa Walther Yoshiharu, Hodas Fabiana Padilha, Ligeiro Melissa Ganeko, Agostinho Daniela Regina, Miana Leonardo Augusto, Tanamati Carla, Gonçalves Rilvani Cavalcante, Penha Juliano Gomes, Massoti Maria Raquel Brigoni, Jatene Marcelo Biscegli, Jatene Fabio Biscegli. Long-Term Effects of Pulmonary Valve Implantation and Prosthesis Evolution in Patients with Repaired Tetralogy of Fallot.. Arquivos brasileiros de cardiologia. 2024. DOI: 10.36660/abc.20230585.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.