DOI 10.1016/j.jaapos.2022.09.008

Медицинская библиотека · Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus · 2022

The contribution of intraocular lens calculation accuracy to the refractive error predicted at 10 years in the Infant Aphakia Treatment Study.

Oke Isdin, VanderVeen Deborah K, McClatchey Thaddeus S, Lambert Scott R, McClatchey Scott K, Infant Aphakia Treatment Study Group

СтатьяПоддержка службы здравоохранения СШАПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To determine the relative contribution of intraocular lens (IOL) calculation accuracy and ocular growth variability to the long-term refractive error predicted following pediatric cataract surgery.

METHODS

Pseudophakic eyes of children enrolled in the Infant Aphakia Treatment Study (IATS) were included in this study. Initial absolute prediction error (APE) and 10-year APE were calculated using the initial biometry, IOL parameters, postoperative refractions, and mean rate of refractive growth. The cohort was divided into children with a low-initial APE (≤1.0 D) and a high-initial APE ( >1.0 D). The 10-year APE was compared between the two groups using the Mann-Whitney U test. Linear regression was used to estimate the variability in prediction error explained by the initial IOL calculation accuracy.

RESULTS

Forty-two children with IOL placement in infancy were included. Seventeen eyes had a low initial APE, and 25 eyes had a high initial APE. There was no significant difference in APE 10 years following surgery between individuals with a low initial APE (median, 2.67 D; IQR, 1.61-4.12 D) and a high initial APE (median, 3.45 D; IQR, 1.64-5.10 D) (P = 0.7). Initial prediction error could explain 12% of the variability in the prediction error 10 years following surgery.

CONCLUSIONS

IOL calculation accuracy contributed minimally to the refractive error predicted 10 years after cataract surgery in the setting of high variability in the rate of refractive growth.

Для цитирования: Oke Isdin, VanderVeen Deborah K, McClatchey Thaddeus S, Lambert Scott R, McClatchey Scott K, Infant Aphakia Treatment Study Group. The contribution of intraocular lens calculation accuracy to the refractive error predicted at 10 years in the Infant Aphakia Treatment Study.. Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus. 2022. DOI: 10.1016/j.jaapos.2022.09.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.