Effective lens position and pseudophakic refraction prediction error at 10½ years of age in the Infant Aphakia Treatment Study.

VanderVeen Deborah K, McClatchey Thaddeus S, McClatchey Scott K, Nizam Azhar, Lambert Scott R, Infant Aphakia Treatment Study Group

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

BACKGROUND

The refraction prediction error (PE) for infants with intraocular lens (IOL) implantation is large, possibly related to an effective lens position (ELP) that is different than in adult eyes. If these eyes still have nonadult ELPs as they age, this could result in persistently large PE. We aimed to determine whether ELP or biometry at age 10½ years correlated with PE in children enrolled in the Infant Aphakia Treatment Study (IATS).

METHODS

We compared the measured refraction of eyes randomized to primary IOL implantation to the "predicted refraction" calculated by the Holladay 1 formula, based on biometry at age 10½ years. Eyes with incomplete data or IOL exchange were excluded. The PE (predicted - measured refraction) and absolute PE were calculated. Measured anterior chamber depth (ACD) was used to assess the effect of ELP on PE. Multiple regression analysis was performed on absolute PE versus axial length, corneal power, rate of refractive growth, refractive error, and best-corrected visual acuity.

RESULTS

Forty-three eyes were included. The PE was 0.63 ± 1.68 D; median absolute PE, 0.85 D (IQR, 1.83 D). The median absolute PE was greater when the measured ACD was used to calculate predicted refraction instead of the standard A-constant (1.88 D [IQR, 1.72] D vs 0.85 D [IQR, 1.83], resp. [P = 0.03]). Absolute PE was not significantly correlated with any other parameter.

CONCLUSIONS

Variations in ELP did not contribute significantly to PE 10 years after infant cataract surgery.

Для цитирования: VanderVeen Deborah K, McClatchey Thaddeus S, McClatchey Scott K, Nizam Azhar, Lambert Scott R, Infant Aphakia Treatment Study Group. Effective lens position and pseudophakic refraction prediction error at 10½ years of age in the Infant Aphakia Treatment Study.. Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus. 2022. DOI: 10.1016/j.jaapos.2022.04.010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.