MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1212/wnl.0000000000003333

Медицинская библиотека · Neurology · 2016

Electromyographic decoding of response to command in disorders of consciousness.

Lesenfants Damien, Habbal Dina, Chatelle Camille, Schnakers Caroline, Laureys Steven, Noirhomme Quentin

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To propose a new methodology based on single-trial analysis for detecting residual response to command with EMG in patients with disorders of consciousness (DOC), overcoming the issue of trial dependency and decreasing the influence of a patient's fluctuation of vigilance or arousal over time on diagnostic accuracy.

METHODS

Forty-five patients with DOC (18 with vegetative/unresponsive wakefulness syndrome [VS/UWS], 22 in a minimally conscious state [MCS], 3 who emerged from MCS [EMCS], and 2 with locked-in syndrome [LIS]) and 20 healthy controls were included in the study. Patients were randomly instructed to either move their left or right hand or listen to a control command ("It is a sunny day") while EMG activity was recorded on both arms.

RESULTS

Differential EMG activity was detected in all MCS cases displaying reproducible response to command at bedside on multiple assessments, even though only 6 of the 14 individuals presented a behavioral response to command on the day of the EMG assessment. An EMG response was also detected in all EMCS and LIS patients, and 2 MCS patients showing nonreflexive movements without command following at the bedside. None of the VS/UWS presented a response to command with this method.

CONCLUSIONS

This method allowed us to reliably distinguish between different levels of consciousness and could potentially help decrease diagnostic errors in patients with motor impairment but presenting residual motor activity.

Для цитирования: Lesenfants Damien, Habbal Dina, Chatelle Camille, Schnakers Caroline, Laureys Steven, Noirhomme Quentin. Electromyographic decoding of response to command in disorders of consciousness.. Neurology. 2016. DOI: 10.1212/wnl.0000000000003333.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.