Аннотация

BACKGROUND

New, small-target (< 1 degree) random dot stereogram (STRDS) and binocular suppression (STBS) tests appropriate for preschool vision screening were developed to correct the shortcomings of previous such tests, particularly missed cases of anisometropic amblyopia such as found with some RDS-based testing.

METHODS

In Experiment 1, the tests were administered to 14 patients with current or a recent history of moderate (< or = 20/60) anisometropic amblyopia, or with accommodative esotropia or monofixation syndrome. All subjects had good binocularity (< or = 100" contour stereoacuity). In Experiment 2, the new tests were administered in a screening setting to a group of 112 three- to five-year-olds to determine testability. Visual acuity, cover testing, and photoscreening were administered as control measures.

RESULTS

In Experiment 1, eleven of the 14 patients failed both tests. Two anisometropic amblyopes passing one or both tests had an acuity < or = 20/30 in the worse eye and < or = 25" stereoacuity. Three anisometropic amblyopia patients failing the STRDS passed another RDS test with similar disparity but a larger target size, confirming a report34 that anisometropic amblyopes may pass RDS testing with parafoveal stereopsis despite the presence of central suppression. The STRDS and STBS tests indicated 80% and 96% specificity, respectively, with the original methodologies; STRDS specificity increased to 95% with retesting with a different methodology. Administration time was 30 sec to 60 sec per test.

CONCLUSION

Small-target RDS or suppression testing may be more effective for strabismus and amblyopia screening of preschoolers than previous RDS test formats.

Для цитирования: Simons K, Avery K E, Novak A. Small-target random dot stereogram and binocular suppression testing for preschool vision screening.. Journal of pediatric ophthalmology and strabismus. 1996. DOI: 10.3928/0191-3913-19960301-09.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.