MedElevator Войти в исследования
Открытая медицинская библиотека

Литература по диагнозу
Z49.2 · Другой вид диализа

Медицинские публикации, первоисточники и полные тексты.
Для клинического вопроса, нового знания и следующего исследования.

Доступно в поиске

158 публикаций

Поиск: 10 мс
Публикации на разных языках · PubMed, Europe PMC и данные издателей через Crossref · 1 с найденным полным текстом

Intelligent "Internet Plus" services in the first case of home hemodialysis in mainland China.

BACKGROUND: Many studies have shown that compared with those who use other dialysis modalities, patients using home hemodialysis (HHD) have an increased rate of survival and better quality of life. It was noted in 2006 that there was opportunity for significant expansion of the use of HHD in many countries. China covers a vast area and has a large amount of end-stage renal failure patients. But in mainland China, all dialysis treatments are in-center, and the number of HHD patients is zero. In 2018, our hospital received the permission of the Shanghai government to carry out HHD. CASE PRESENT

Клинический случайПоддержка исследования: вне правительства СШАСтатьяПоиск полного текста в очередиПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

PMID 34121321Открыть статью

Arteriovenous Fistula-induced Cardiac Remodeling Shows Cardioprotective Features in Mice.

OBJECTIVE---: Arteriovenous fistulae (AVF) placed for hemodialysis have high flow rates that can stimulate left ventricular (LV) hypertrophy. LV hypertrophy generally portends poor cardiac outcomes, yet clinical studies point to superior cardiac-specific outcomes for patients with AVF when compared to other dialysis modalities. We hypothesize that AVF induce physiologic cardiac hypertrophy with cardioprotective features. METHODS---: 9-11 week C57Bl/6 male and female mice were treated with sham laparotomy or an aortocaval fistula via a 25Ga needle. Cardiac chamber size and function were assess

СтатьяПоиск полного текста в очередиПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

PMID 34423320Открыть статью

Using Focus Groups to Understand Dialysis Staff Perspectives on Delivering Transplant Education.

INTRODUCTION: Kidney transplant education in dialysis facilities could be optimized with internet resources, like videos, but most qualitative research predates widespread availability of online video education about kidney transplantation. To improve understanding of dialysis staff transplant education practices, as well as the potential value of video, we conducted focus groups of dialysis center staff members in Buffalo, NY. METHODS/APPROACH: Seventeen focus groups (97 participants: 53 nurses, 10 dialysis technicians, 6 social workers, 6 dieticians, 7 administrative personnel, 2 trainees,

СтатьяПоддержка NIH: внешняя программаПоиск полного текста в очередиПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

PMID 34873981Открыть статью

Assessment of cerebral oxygenation response to hemodialysis using near-infrared spectroscopy (NIRS): Challenges and solutions.

To date, the clinical use of functional near-infrared spectroscopy (NIRS) to detect cerebral ischemia has been largely limited to surgical settings, where motion artifacts are minimal. In this study, we present novel techniques to address the challenges of using NIRS to monitor ambulatory patients with kidney disease during approximately eight hours of hemodialysis (HD) treatment. People with end-stage kidney disease who require HD are at higher risk for cognitive impairment and dementia than age-matched controls. Recent studies have suggested that HD-related declines in cerebral blood flow mi

СтатьяПоиск полного текста в очередиПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

PMID 35173820Открыть статью

Normal white blood cell counts predict long-term mortality of hemodialysis patients.

PURPOSE: It is unclear whether normal white blood cell (WBC) counts are predictive of subsequent mortality in hemodialysis patients. METHODS: All patients aged 17 years or more, who initiated hemodialysis at a tertiary Hospital from January 2000 to August 2017 with a dialysis vintage of greater than 90 days and normal median WBC count of their first dialysis year were included in the study. They were followed until they died, transferred to other dialysis facilities, switched to peritoneal dialysis, received a renal transplant or reached the end of the study (August 31, 2018). Cox regression

СтатьяНаблюдательное исследованиеПоиск полного текста в очередиПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

PMID 32157617Открыть статью

Successful Dialysis Treatment of Metformin Associated Lactic Acidosis, Report of Two Cases.

INTRODUCTION: Metformin-associated lactic acidosis is rare despite its widespread use. It is often associated with the use of metformin in the presence of chronic kidney disease, but it may also occur in people with normal renal function in the case of acute overdose. CASE REPORT: 20 years old (patient 1) and 37 years old (patient 2) women without any chronic disease took 40 gram (727 mg/ kg) and 60 gram (1200 mg/kg) metformin, respectively; for the suicidal attempt. Deep lactic acidosis was detected in patients. In patient 1, hemodialysis was performed for 4 hours. After the interruption, de

Клинический случайСтатьяПоиск полного текста в очередиПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

PMID 32165603Открыть статью

Complications and outcomes of urgent-start peritoneal dialysis in elderly patients with end-stage renal disease in China: a retrospective cohort study.

OBJECTIVES: To investigate the complications and survival of elderly patients with end-stage renal disease (ESRD) who received urgent-start peritoneal dialysis (USPD) or urgent-start haemodialysis (USHD), and to explore the value of peritoneal dialysis (PD) as the emergent dialysis method for elderly patients with ESRD. DESIGN: Retrospective cohort study. SETTING: Two tertiary care hospitals in Shanghai, China. PARTICIPANTS: Chinese patients (n=542) >65 years of age with estimated glomerular filtration rate ≤15 mL/min/m2 who received urgent-start dialysis between 1 January 2005 and 31 Decem

СтатьяПоддержка исследования: вне правительства СШАПоиск полного текста в очередиПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

PMID 32205371Открыть статью

Serologic Detection of SARS-CoV-2 Infections in Hemodialysis Centers: A Multicenter Retrospective Study in Wuhan, China.

RATIONALE & OBJECTIVE: Patients receiving maintenance hemodialysis (MHD) are highly vulnerable to infection with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The current study was designed to evaluate the prevalence of SARS-CoV-2 infection based on both nucleic acid testing (NAT) and antibody testing in Chinese patients receiving MHD. STUDY DESIGN: Cross-sectional study. SETTING & PARTICIPANTS: From December 1, 2019, to March 31, 2020, a total of 1,027 MHD patients in 5 large hemodialysis centers in Wuhan, China, were enrolled. Patients were screened for SARS-CoV-2 infection

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеПоддержка исследования: вне правительства СШАПоиск полного текста в очередиПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

PMID 32628990Открыть статью

Reasons for long-term tunneled dialysis catheter use and associated morbidity.

OBJECTIVE: Tunneled dialysis catheters (TDCs) are generally used as a temporary means to provide hemodialysis until permanent arteriovenous (AV) access is established. However, some patients may have long-term catheter-based hemodialysis because of the lack of alternatives for other dialysis access. Our objective was to evaluate characteristics of patients with, reasons for, and mortality associated with long-term TDC use. METHODS: A retrospective single-institution analysis was performed. Long-term TDC use was defined as >180 days without more than a 7-day temporary removal time. Reasons for

Сравнительное исследованиеСтатьяПоиск полного текста в очередиПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

PMID 32707393Открыть статью

Three years' experience of dialysis event surveillance.

BACKGROUND: The main study aim was to track infections, evaluate performance, and identify opportunities for improved practice since infections, especially those associated with multidrug-resistant organisms, are the second most common cause of death among end-stage renal disease patients. METHODS: This study describes the establishment of baseline dialysis event surveillance at a large dialysis center. Every month, the dialysis center staff reported the total number of maintenance hemodialysis patients to the department of infection control and hospital epidemiology. The surveillance system

СтатьяПоиск полного текста в очередиПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

PMID 30736969Открыть статью

Patients with lower extremity dialysis access have poor primary patency and survival.

OBJECTIVE: Lower extremity arteriovenous (AV) access is an alternative when upper extremity access options have been exhausted. Our goal was to assess short- and medium-term outcomes of lower extremity hemodialysis access. METHODS: The Vascular Quality Initiative was reviewed for all lower extremity AV hemodialysis cases. Patient and case details were recorded. Multivariable analysis was used to analyze outcomes. RESULTS: We identified 463 lower extremity AV access cases in the VQI registry. There were 56 AVF (12.1%) and 407 AVG (87.9%). The mean age was 56 ± 15 years, 46.9% were male, and 4

СтатьяМногоцентровое исследованиеПоиск полного текста в очередиПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

PMID 31147128Открыть статью

Healthcare costs of patients on different renal replacement modalities - Analysis of Dutch health insurance claims data.

BACKGROUND: The aim of this study is to present average annual healthcare costs for Dutch renal replacement therapy (RRT) patients for 7 treatment modalities. METHODS: Health insurance claims data from 2012-2014 were used. All patients with a 2014 claim for dialysis or kidney transplantation were selected. The RRT related and RRT unrelated average annual healthcare costs were analysed for 5 dialysis modalities (in-centre haemodialysis (CHD), home haemodialysis (HHD), continuous ambulatory peritoneal dialysis (CAPD), automated peritoneal dialysis (APD) and multiple dialysis modalities in a yea

СтатьяПоддержка исследования: вне правительства СШАПоиск полного текста в очередиПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

PMID 31415578Открыть статью

Reversed connection of cuffed, tunneled, dual-lumen catheters with increased blood flow rate maintains the adequacy of delivered dialysis despite the higher access recirculation.

PURPOSE: Reversing the connection mode of permanent dual-lumen dialysis catheters results in higher access recirculation that may compromise the dialysis adequacy. The purpose of this study is to investigate the effect of reversed-connected dialysis with a higher versus a standard blood flow rate (Qb) on adequacy parameters and access recirculation. MATERIALS AND METHODS: In a cross-over design, 46 prevalent dialysis patients with a properly functioning cuffed, tunneled, dual-lumen catheter were evaluated in three consecutive mid-week dialysis sessions. At baseline, participants were evaluate

СтатьяРандомизированное исследованиеПоиск полного текста в очередиПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

PMID 31471844Открыть статью

Intradialytic Cerebral Hypoperfusion as Mechanism for Cognitive Impairment in Patients on Hemodialysis.

The high frequency of cognitive impairment in individuals on hemodialysis is well characterized. In-center hemodialysis patients are disproportionately affected by cognitive impairment compared with other dialysis populations, identifying hemodialysis itself as a possible factor. The pathophysiology of cognitive impairment has multiple components, but vascular-mediated cerebral injury appears to contribute based on studies demonstrating increased cerebral ischemic lesions and atrophy in brain imaging of patients on hemodialysis. Patients on hemodialysis may be at increased risk for cerebral is

СтатьяПоддержка NIH: внешняя программаОбзорПоиск полного текста в очередиПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

PMID 31511363Открыть статью

Study of Biocompatibility of Membranes in Online Hemodiafiltration.

BACKGROUND: The biocompatibility of dialysis membranes is a determining factor in avoiding chronic microinflammation in patients under haemodialysis. Lower biocompatibility has been related to increased inflammatory status, which is known to be associated with cardiovascular events. Classically, cellulose membranes have been considered bioincompatible. A new-generation of asymmetric cellulose triacetate (CTA) membranes allows the performance of high convective transport techniques, but there have been no studies of their biocompatibility. The aim of the present study was to analyze and compare

СтатьяПоддержка исследования: вне правительства СШАПоиск полного текста в очередиПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

PMID 31865336Открыть статью

Health-related quality of life following kidney and simultaneous pancreas kidney transplantation.

INTRODUCTION: Kidney and simultaneous pancreas kidney (SPK) transplant recipients are younger and fitter than most other dialysis patients, but are also more vulnerable in areas of social, emotional and physical interaction. Few studies have tracked their post-transplant health-related quality of life (HRQoL). AIM: To assess HRQoL following kidney and SPK transplantation, with comparison to dialysis patients, people with multiple co-morbidities and general population data. METHODS: Patients completed the Kidney Disease Quality of Life Short Form (KDQOL-SF™) 1.3 to assess their pre-transplant

Сравнительное исследованиеСтатьяПолный текст не найденПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

PMID 30393905Открыть статью

Mathematical and Experimental Validation of Flux Dialysis Method: An Improved Approach to Measure Unbound Fraction for Compounds with High Protein Binding and Other Challenging Properties.

A flux dialysis method to measure unbound fraction (fu) of compounds with high protein binding and other challenging properties was tested and validated. This method is based on the principle that the initial flux rate of a compound through a size-excluding dialysis membrane is proportional to the product of the compound initial concentration, fu, and unbound dialysis membrane permeability (Pmem). Therefore, fu can be determined from the initial concentration and flux rate, assuming membrane Pmem is known. Compound initial flux rates for 14 compounds were determined by dialyzing human plasma c

СтатьяПоддержка исследования: вне правительства СШАПоиск полного текста в очередиПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

PMID 29437872Открыть статью

The impact of blood flow rate on dialysis dose and phosphate removal in hemodialysis patients.

The inadequacy of dialysis and hyperphosphatemia are both associated with morbidity and mortality in chronic hemodialysis (HD) patients. Blood flow rate (BFR) during HD is one of the important determinants of increasing dialysis dose. The aim of this study was to determine the effect of increasing BFR on dialysis dose and phosphate removal. Forty-four patients were included in a cross-sectional study. Each patient received six consecutive dialysis sessions as follows: three consecutive sessions with a BFR of 250 mL/min, followed by three others with BFR of 350 mL/min without changing the other

СтатьяПоиск полного текста в очередиПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

PMID 30152424Открыть статью

Cardiomyocyte proliferation prevents failure in pressure overload but not volume overload.

Induction of the cell cycle is emerging as an intervention to treat heart failure. Here, we tested the hypothesis that enhanced cardiomyocyte renewal in transgenic mice expressing cyclin D2 would be beneficial during hemodynamic overload. We induced pressure overload by transthoracic aortic constriction (TAC) or volume overload by aortocaval shunt in cyclin D2-expressing and WT mice. Although cyclin D2 expression dramatically improved survival following TAC, it did not confer a survival advantage to mice following aortocaval shunt. Cardiac function decreased following TAC in WT mice, but was p

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПоиск полного текста в очередиПеревод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

PMID 29083322Открыть статью

Differences in care burden of patients undergoing dialysis in different centres in the netherlands.

BACKGROUND: A classification model was developed to simplify planning of personnel at dialysis centres. This model predicted the care burden based on dialysis characteristics. However, patient characteristics and different dialysis centre categories might also influence the amount of care time required. OBJECTIVE: To determine if there is a difference in care burden between different categories of dialysis centres and if specific patient characteristics predict nursing time needed for patient treatment. DESIGN: An observational study. PARTICIPANTS: Two hundred and forty-two patients from 12

СтатьяНаблюдательное исследованиеПоиск полного текста в очередиПеревод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

PMID 28244208Открыть статью