Prognostic significance of interictal epileptiform discharges after epilepsy surgery.

Rathore Chaturbhuj, Radhakrishnan Kurupath

СтатьяОбзорПеревод в очереди

Аннотация

The prognostic significance of interictal epileptiform discharges (IED) after epilepsy surgery is uncertain. We reviewed 20 studies (including 2 unpublished data sets) to assess the usefulness of postoperative EEG findings in predicting seizure outcome after resective epilepsy surgery. Patient selection and methodology varied widely among the studies. The published studies included 1,345 patients (temporal resection, n = 751; extratemporal resection, n = 373; unspecified site, n = 221). We defined a favorable outcome as a postoperative seizure status of Engel class I or equivalent. The frequency of postoperative IED ranged from 13% to 68% (mean, 31.5%). Postoperative IED were strongly associated with an unfavorable seizure outcome for the whole cohort (odds ratio, 3.3; 95% confidence interval, 2.5-4.5), for the subgroup of patients who underwent temporal resection (odds ratio, 2.5; 95% confidence interval, 1.6-4.0), and for the extratemporal resection subgroup (odds ratio, 5.6; 95% confidence interval, 3.9-9.3). Postoperative IED had a modest positive predictive value (52%) but an excellent negative predictive value (71%) for unfavorable seizure outcome. Most IED (>90%) were localized to the site of resection and were also influenced by preoperative spike frequency and completeness of resection. Insufficient data preclude any firm conclusions about the value of postoperative IED in predicting seizure outcomes after hemispherotomy or corpus callosotomy.

Для цитирования: Rathore Chaturbhuj, Radhakrishnan Kurupath. Prognostic significance of interictal epileptiform discharges after epilepsy surgery.. Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society. 2010. DOI: 10.1097/wnp.0b013e3181eaa5fa.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.