MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10143-025-03607-w

Медицинская библиотека · Neurosurgical review · 2025

Usefulness of piezoelectric sensor device for monitoring extraocular movement during endoscopic endonasal surgery to remove skull base tumor.

Nakase Kenta, Nishimura Fumihiko, Takatani Tsunenori, Motoyama Yasushi, Yokoyama Shohei, Takeshima Yasuhiro, Matsuda Ryosuke, Nakagawa Ichiro, Yamada Shuichi, Park Young-Soo, Hayashi Hironobu, Kawaguchi Masahiko

СтатьяПеревод в очереди

Аннотация

The present study was conducted to evaluate three modalities used to detect extraocular movement during endonasal endoscopic surgery for a skull base tumor to protect cranial nerves from damage; free-run electrooculography (EOG), piezoelectric sensor (PES), and triggered electromyography (t-EMG) monitoring. Twenty patients (8 males, 12 females; average age 61.8 years) treated for a skull base tumor at Nara Medical University from 2018 to 2021 were enrolled. The three modalities were assessed regarding detection of ocular movement during endoscopic endonasal surgery (EES) for a skull base tumor and the results compared. Oculomotor nerve detection by EOG, PES, and t-EMG was noted in 77.8%, 83.3%, and 33.3%, respectively, of the cases (p = 0.001), while abducent nerve detection was noted in 61.1%, 66.7%, and 16.7%, respectively, (p = 0.002), showing that PES has significantly greater sensitivity for detection of ocular movement. Gross total resection was achieved in nine (45%), near-total resection in three (15%), and partial resection in eight (40%) of the patients. To protect ocular movement function from damage during EES for a skull base tumor, the present findings indicate that among the three modalities tested, PES is compact and useful, and most safe for avoiding complications.

Для цитирования: Nakase Kenta, Nishimura Fumihiko, Takatani Tsunenori, Motoyama Yasushi, Yokoyama Shohei, Takeshima Yasuhiro, Matsuda Ryosuke, Nakagawa Ichiro, Yamada Shuichi, Park Young-Soo, Hayashi Hironobu, Kawaguchi Masahiko. Usefulness of piezoelectric sensor device for monitoring extraocular movement during endoscopic endonasal surgery to remove skull base tumor.. Neurosurgical review. 2025. DOI: 10.1007/s10143-025-03607-w.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.