MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12891-022-06053-7

Медицинская библиотека · BMC musculoskeletal disorders · 2022

Three-dimensional printed customized uncemented unipolar prosthesis combined with ligament reconstruction for tumorous defect of the distal femur in children.

Li Zhuangzhuang, Lu Minxun, Zhang Yuqi, You Qi, Wang Yitian, Li Longqing, Ye Qiang, Wang Yang, Luo Yi, Min Li, Zhou Yong, Tu Chongqi

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Hemiarthroplasty following tumor resection of the distal femur in children provides a chance to preserve the proximal tibial physis for limb elongation. Based on three-dimensional (3D) printing technology, the uncemented unipolar prosthesis with joint stability reinforced structures (JSRSs) was custom-designed for our cases. This study aimed to describe the design and assess the short-term outcomes of this refined prosthetic hemiarthroplasty.

METHODS

Seven patients (four females and three males) received 3D-printed customized uncemented unipolar prosthesis for hemiarthroplasty after removal of the distal femur, from September 2019 to October 2020 at our Orthopedics department. The limb function, growth of the preserved proximal tibial physis, joint stability, and limb length discrepancy (LLD) were assessed. Complications were recorded.

RESULTS

Six patients survived with no evidence of metastasis or local recurrence at the last follow-up, and one patient died of lung metastasis at 19 months postoperatively. Follow-up ranged from 19 to 32 months, with an average of 26 months. Elongation of the tibia was observed in all cases. At the last follow-up, four patients exhibited equal growth length compared with the healthy contralateral tibia. LLD ranged from 0.8 to 1.6 cm with a mean of 1.3 cm. The average knee range of motion was 95.3° of flexion and 4.5° of extension. All patients achieved satisfactory postoperative limb function with a mean MSTS score of 25.8. The results of the drawer, Lachman, and pivot shift tests were negative in all patients. During follow-up, painless joint space narrowing was observed in two patients. The screw for ligament fixation loosened in one of the seven patients at 17 months postoperatively. No subluxation of the joint, angular deformity, or breakage of the implant was detected in the remaining patients.

CONCLUSIONS

3D-printed customized uncemented unipolar prosthesis with JSRS would be a good choice for reconstructing tumorous defect in the distal femur in children.

Для цитирования: Li Zhuangzhuang, Lu Minxun, Zhang Yuqi, You Qi, Wang Yitian, Li Longqing, Ye Qiang, Wang Yang, Luo Yi, Min Li, Zhou Yong, Tu Chongqi. Three-dimensional printed customized uncemented unipolar prosthesis combined with ligament reconstruction for tumorous defect of the distal femur in children.. BMC musculoskeletal disorders. 2022. DOI: 10.1186/s12891-022-06053-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.