The safety and accuracy of intratumoral catheter placement to infuse viral immunotherapies in children with malignant brain tumors: a multi-institutional study.

Многоцентровое исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Barkley Ariana, Butler Eric, Park Christine, Friedman Allan, Landi Daniel, Ashley David M, Bigner Darell, Bernstock Joshua D, Friedman Gregory K, Johnston James M, Thompson Eric M

Аннотация

OBJECTIVE: Relatively little is known about the safety and accuracy of catheter placement for oncolytic viral therapy in children with malignant brain tumors. Accordingly, this study combines data from two phase I clinical trials that employed viral immunotherapy across two institutions to describe the adverse event profile, safety, and accuracy associated with the stereotactic placement and subsequent removal of intratumoral catheters.

METHODS: Children with progressive/recurrent supratentorial malignant tumors were enrolled in two clinical trials (NCT03043391 and NCT02457845) and treated with either the recombinant polio:rhinovirus (lerapolturev) or the genetically modified oncolytic herpesvirus (G207). Age, sex, race, tumor diagnosis, and tumor location were analyzed. Events related to the catheter placement or removal were categorized. A catheter that was either pulled back or could not be used was defined as "misplaced." Neuronavigation software was used to analyze the accuracy of catheter placement for NCT03043391. Descriptive statistics were performed.

RESULTS: Nineteen patients were treated across the two completed trials with a total of 49 catheters. The mean ± SD (range) age was 14.1 ± 3.6 (7-19) years. All tumors were grade 3 or 4 gliomas. Nonlobar catheter tip placement included the corpus callosum, thalamus, insula, and cingulate gyrus. Six of 19 patients (31.6%) had minor hemorrhage noted on CT; however, no patients were symptomatic and/or required intervention related to these findings. One of 19 patients had a delayed CSF leak after catheter removal that required oversewing of the surgical site. No patients developed infection or a neurological deficit. In 7 patients with accuracy data, the mean ± SD distance of the planned trajectory (PT) to the catheter tip was 1.57 ± 1.6 mm, the mean angle of the PT to the catheter was 2.43° ± 2.1°, and the greatest distance of PT to the catheter in the parallel plane was 1.54 ± 1.5 mm. Three of 49 (6.1%) catheters were considered misplaced.

CONCLUSIONS: Although instances of minor hemorrhage were encountered, they were clinically asymptomatic. One of 49 catheters required intervention for a CSF leak. Congruent with previous studies in the literature, the stereotactic placement of catheters in these pediatric tumor patients was accurate with approximately 95% of catheters having been adequately placed.